Case IH AFX8010 — PRIMARY HYDRAULIC POWER SYSTEM

DISTRIBUTION SYSTEMS - PRIMARY HYDRAULIC POWER SYSTEM Hydraulic Systems The pump will remain in the high-pressure standby mode until the load is overcome or the valve is returned to neutral. When the valve is returned to neutral, pressure is no longer available to the signal line. The flow compensator spool will shift allowing oil to extend the control piston and destroke the pump. Signal line pressure is bled-off through a 0.5 mm (0.020 ) signal orifice check valve threaded into the steering priory valve, a 0.89 mm (0.035 ) dampening orifice located in the steering priority valve, a 0.78 mm (0.031 ) orifice in the steering hand pump and then to the reservoir.

When the signal pressure is bled-off, the flow compensator spool will return the system to low pressure standby. High Pressure Standby Should the hydraulic system stall-out under a high load, or a cylinder reach the end of its stroke, the pump will go into high-pressure standby until the load is overcome or the valve is returned to neutral. When the system stalls-out, there will be no flow across the controlling valve. The pressure will then equalize on both ends of the flow compensator spool. The spring will then cause the flow compensator spool to shift. At the same time, the pressure will start to rise in the system until it is able to move the spring-loaded high-pressure spool.

This spring is set at 182.85--189.75 bar (3050 psi). When the high-pres- sure compensator spool shifts, it directs oil to the swash plate control piston, de-stroking the pump. 1. Signal Line-In 2. Flow Control Spool 3. High Pressure Spool 4. To Control Piston 5. Drain to Tank 6. Pump Output A. Maximum High Pressure Oil B. Drain Oil A.10.A / 28