DISTRIBUTION SYSTEMS - LIGHTING SYSTEM Turn/hazard light - Overview (A.40.A.13 - C.10.A.10) AFX8010 HAZARD LIGHTS CIRCUIT NOTE: Failed bulbs, poor connections, or broken circuitry may cause the flashers to flash on and off at an irregular pace. If trailer lights are connected, the lighting system will function differently. For example, when trailer lights are connected to the lighting circuit, a bulb failure will have less affect on the operation of the circuit. Wiring harness - Electrical schematic frame 33 (A.30.A.88 - C.20.E.33) Current travels from the electrical system buss bar and passes through fuse F-56 (15-amp) and connector X033 to reach a wire splice.
The wire splice directs current to two different paths: The first path sends current through connector X255 to reach pin 1 of the Flasher Module (A-05). Current reaching pin 1 of the Flasher Module provides power for the module to function. The ground path exits pin 6 and travels through a wire splice and connector X033 to reach the cab floor ground location #3. This provides power for the Flasher Module to function. The second path sends current to pin 2 of the Hazard Switch (S-25). When the hazard switch is moved to the ON position, current crosses from pin 2 to reach pin 3. An internal jumper also sends current through pin 7 to reach the indicator lamp within the switch.
The ground path for the internal indicator lamp exits pin 9 and passes through a wire splice and connector X033 to reach the cab floor ground location #3. This causes the internal indicator lamp to illuminate. Current travels from pin 3 to reach a wire splice. The wire splice sends current to two different paths: The first path sends current through connectors X033 and X015 to reach pin J1-15 of CCM-2. This informs the network that the hazard switch has been activated. When the hazard switch is activated, the following work lights are disabled: LH Cab Inner Work Light (E-17) will only operate in "Low Beam" mode. RH Cab Inner Work Light (E-18) will only operate in "Low Beam" mode.
LH Lower Work Light (E-23) RH Lower Work Light (E-24) Unload Tube Light (E-29) LH Rear Work Light (E-27) RH Rear Work Light (E-28) LH HID Field Lights (E-60) RH HID Field Lights (E-61) The second path sends current to pin 2 of the Flasher Module (A-05). The Flasher Module energizes and sends pulsing current from pins 3 and 4. PIN 3 of the Flasher Module Pulsing current exits pin 3 and reaches a wire splice. The wire splice directs current to two paths: The first path sends pulsing current through connector X257 to reach pin 7 of the Turn Indicator (Left) (E-09) found on the steering column.
The ground path exits pin 9 and travels through a wire splice and connector X033 to reach the cab floor ground location #3. This causes the left light within the turn indicator to flash on and off. The second path sends pulsing current through connectors X033 and X005 to reach a wire splice. Wiring harness - Electrical schematic frame 34 (A.30.A.88 - C.20.E.34) The wire splice sends pulsing current to three different paths: Wiring harness - Electrical schematic frame 33 (A.30.A.88 - C.20.E.33) The first path (North American models only) sends pulsing current through connector X008 and connector X007 to reach connector X032 .
If a header is equipped, the header harness is used to send pulsing current through connector X303 to the LH Header Flashing Lamp (NA) (E-01). The ground path exits connector X303 and passes through a wire splice, connector X032 , and connector X071 to reach the front frame ground location #2. This causes the LH Header Flashing Lamp (NA) (E-01) to flash on and off. Wiring harness - Electrical schematic frame 34 (A.30.A.88 - C.20.E.34) The second path sends pulsing current through connector X160 to a wire splice. The wire splice sends pulsing current to the LH Front Hazard Lamp (E-03) (All Markets) and the LH Flashing Lamp (E-52) (European Models Only).
The ground path for the lights travels through a wire splice and connector X160 to reach the front frame ground location 9668 1 27/05/2004 A.40.A / 13