DISTRIBUTION SYSTEMS - LIGHTING SYSTEM Back light - Overview (A.40.A.24 - C.10.A.10) AFX8010 Backlighting is provided to illuminate the gauges and switches within the cab of the combine. The backlighting circuit consists of two different groups. GROUP 1 - The first group of backlights are powered any time the key switch is in the "Start" or "Run" positions. These backlights are found along the right side of the operator in the Propulsion Handle (S-03), the Front Switch Panel (A-13), and the Rear Switch Panel (A-18).
Wiring harness - Electrical schematic frame 28 (A.30.A.88 - C.20.E.28) When the Key Switch (S-02) is turned to the "Start" or "Run" positions, current exits connector X068 pin 6 and passes through a wire splice to reach CCM-1 Power Relay (K-24) , CCM-2 Power Relay (K-25), and CCM-3 Cab Power Relay (K-26). The ground path to the three relays is completed through CCM-1 module connector X018 pin J1-23. This causes the three relays to energize. Current is sent from pin 5 of CCM-3 Cab Power Relay (K-26) to reach electrical system buss bar K-26. Current passes through the buss bar to reach RH Console Fuse F-48.
Wiring harness - Electrical schematic frame 25 (A.30.A.88 - C.20.E.25) Current travels through fuse F-48 and connector X001 and a wire splice to reach another wire splice. The wire splice sends current to the following components: Propulsion Handle (S-03, A-17) - Wiring harness - Electrical schematic frame 25 (A.30.A.88 - C.20.E.25) Current enters connector X059 pin 1 of the Propulsion Handle (S-03, A-17) and reaches the backlighting circuit in the handle. The ground path to the backlights exits pin 2 and travels through a wire splice and connector X001 to reach the Cab Floor Ground location #3. This causes the backlights to illuminate.
Front Switch Panel (A-13) - Wiring harness - Electrical schematic frame 25 (A.30.A.88 - C.20.E.25) Current enters connector X386 pin 1 of the Front Switch Panel (A-13) and reaches the backlighting. The ground path to the backlights exits pin 15 and travels through a wire splice and connector X001 to reach the Cab Floor Ground location #3. This causes the backlights to illuminate. Rear Switch Panel (A-18) - Wiring harness - Electrical schematic frame 25 (A.30.A.88 - C.20.E.25) Current enters connector X387 pin 5 of the Rear Switch Panel (A-18) and reaches the backlighting.
The ground path to the backlights exits pin 6 and travels through a wire splice and connector X001 to reach the Cab Floor Ground location #3. This causes the backlights to illuminate. GROUP 2 - The second group of backlights are powered whenever the following circuits are activated:
Road Light Circuit - Head light - Overview (A.40.A.11 - C.10.A.10) Marker Light Circuit - Marker light - Overview (A.40.A.12 - C.10.A.10) Front Work Light Circuit - Front work light - Overview (A.40.A.16 - C.10.A.10) Side Work Light Circuit - Side work light - Overview (A.40.A.18 - C.10.A.10) Rear Work Light Circuit - Rear work light - Overview (A.40.A.17 - C.10.A.10) Activating the circuits listed above causes a message to be sent across the network. CCM-2 receives this message and sends current from connector X015 pin J1-11 to splice block C (W-03) connector X133 pin B. This provides power to the backlights within the following components:
9668 1 27/05/2004 A.40.A / 29 CCM-2 Pin ID (Backlighting) Splice Block C (W-03) Pin ID Circuit Frame # Pin A Console Light E-35, connector X138 Wiring harness - Electrical schematic frame 38 (A.30.A.88 - C.20.E.38) Pin B Power (+) from CCM-2 connector X015 pin J1-11 Wiring harness - Electrical schematic frame 27 (A.30.A.88 - C.20.E.27) Pin C Rear Work light Switch S-44, connector X131 Wiring harness - Electrical schematic frame 40 (A.30.A.88 - C.20.E.40)