DISTRIBUTION SYSTEMS - LIGHTING SYSTEM Turn/hazard light Flasher unit - Testing (A.40.A.13.86 - G.40.A.20) AFX8010 9668 1 27/05/2004 A.40.A / 40 A-05 Flasher Module E-13 LH Road Light (EU) E-14 RH Road Light (EU) F-32 High Beam Fuse F-33 Low Beam Fuse (EU) F-51 Horn, Marker Lights Fuse H-02 Horn K-02 Light Control Relay K-04 High Beam Relay (EU) K-05 Low Beam Relay (EU) S-26 Road Light Switch N° Test Point Expected Result Other Result (Possible Cause) 1 Measure for 12 volts at Flasher Module A-05 connector X255 (pin 1). 12 volts If good reading, go to next test point. Open in power feed circuit between Flasher Module A-05 connector X255 (pin 1) and Fuse #56.

Short to ground, which affect circuit between Flasher Module A-05 connector X255 (pin 1) and Fuse #56 (see test A-Hazard Switch Test, steps 1-4). 2 Close the Hazard Switch S-25 Measure for 12 volts at Flasher Module A-05 connector X255 (pin 2). 12 volts If good reading, go to next test point. Open in circuit 207 (PU) or 179 (PU) between Flasher Module A-05 connector X255 (pin 2) and Hazard Switch S-25 (pin 3). Perform Hazard Switch Test. 3 Place Road Light Switch in LEFT turn position. Measure for 12 volts at the Road Light Switch S-26 connector X256 (pin 2). 12 volts If good reading, go to next test point. Perform Road Light Switch Test.

4 Measure for 12 volts at Flasher Module A-05 connector X255 (pin 7). 12 volts If good reading, go to next test point. Open in circuit 201 (PU) or 203 (PU) between Flasher Module A-05 connector X255 (pin 7) and Road Light Switch S-26 connector X256(pin 2). 5 Place Road Light Switch in RIGHT turn position. Measure for 12 volts at the Road Light Switch S-26 connector X256 (pin 3). 12 volts If good reading, go to next test point. Perform Road Light Switch Test. 6 Measure for 12 volts at Flasher Module A-05 connector X255 (pin 8). 12 volts If good reading, go to next test point.

Open in circuit 197 (PU) or 202 (PU) between Flasher Module A-05 connector X255 (pin 8) and Road Light Switch S-26 connector X256(pin 3). 7 Disconnect the Flasher Module A-05. Measure resistance on circuit 141 (BK) between Flasher Module A-05 connector X255 (pin 6) and ground. Less than 1 ohms. Open in circuit 141 (BK) between the Flasher Module A-05 connector X255 (pin 6) and ground. 8 Reconnect the Flasher Module A-05. Place Hazard Switch S-25 in the .ON. position. Measure for voltage at Flasher Module A-05 connector X255 (pins 3 and 4). 0 to 12 volts If good reading, go to test point 13. Flasher Module A-05.

Short to ground on circuit 199 (PU), 200 (PU), 195 (PU) or 196 (PU) between Flasher Module A-05 connector X255 (pins 3 and 4) and Turn Indicator E-09 and flashing lamps. Go to next test point. 9 Test Point Good Reading Possible Cause of Bad Reading 9 Disconnect the Flasher Module A-05. Place a jumper wire across pins 1 and 4 of the Flasher Module A-05 connector X255. LH flashing lamps illuminate. If good reading, go to next test point Short to ground will blow Fuse #56. Repair short to ground.