DISTRIBUTION SYSTEMS - LIGHTING SYSTEM 9668 1 27/05/2004 A.40.A / 41 N° Test Point Expected Result Other Result (Possible Cause) 10 Disconnect the Flasher Module A-05. Place a jumper wire across pins 1 and 3 of the Flasher Module A-05 connector X255. RH flashing lamps illuminate. If good reading, go to next test point. Short to ground will blow Fuse #56. Repair short to ground. 11 Reconnect the Flasher Module A-05. Place Hazard Switch S-25 in the "ON"position. Measure for voltage at Turn Indicator E-09 connector X257 (pins 7 and 10). 0 to 12 volts If good reading, go to next test point.
Open circuit 199 (PU) or 196 (PU) between Flasher Module A-05 connector X255 (pins 3 and 4) and Turn Indicator E-09 connector X257 (pins 7 and 10). 12 Measure resistance on circuit 209 (BK) between Turn Indicator E-09 connector X257 (pin 9) and ground. Less than 1 ohms. If good reading, go to next test point. Turn Indicator E-09 Open in circuit 141 (BK) between the Flasher Module A-05 connector X255 (pin 6) and ground. 13 Measure 12 volts at Flasher Module A-05 connector X255 (pin 5). 12 voltsIf good reading, go to text point 16. Flasher Module A-05. Short to ground on circuit 208 (PU) between Flasher Module A-05 connector X255 (pin 5) and High Beam Indicator E-10 connector X258 (pin 7).
Go to next test point. 14 Disconnect the Flasher Module A-05. Place a jumper wire across pins 1 and 5 of the Flasher Module A-05 connector X255. High Beam Indicator E-10 illuminates. If good reading, go to next test point. Short to ground on circuit 208 (PU) will blow Fuse #56. Repair short to ground between Flasher Module A-05 connector X255 (pin 5) and High Beam Indicator E-10 connector X258 (pin 7). 15 Measure resistance on circuit 221 (BK) between High Beam Indicator E-10 connector X258 (pin 9) and ground. Less than 1 ohms If good reading, check High Beam Indicator E-10. Open circuit 221 (BK) between High Beam Indicator E-10 connector X258(pin 9) and ground.
16 Place Hazard Switch S-25 in the "ON" position. Measure the voltage at Flasher Module A-05 connector X255 (pin 10). 0 to 12 volts If good reading, go to test point 17. Flasher Module A-05. Short to ground on circuit 243 (PU) between Flasher Module A-05 connector X255 (pin 10) and LH NASO Flashing Lamp E-07 connector X242 (pin A). Go to next test point. 17 Disconnect the Flasher Module A-05. Place a jumper wire across pins 1 and 10 of the Flasher Module A-05 connector. LH NASO Flashing Lamp E-07 illuminates. If good reading, go to next test point. Short to ground on circuit 243 (PU) will blow Fuse #56.
Repair short to ground on circuit 243 (PU) between Flasher Module A-05 connector X255 (pin 10) and LH NASO Flashing Lamp E-07 connector X242 (pin A). 18 Measure the voltage at Flasher Module A-05 connector X255 (pin 11). 0 to 12 volts Flasher Module A-05. Short to ground on circuit 244 (PU) between Flasher Module A-05 connector X255 (pin 11) and RH NASO Flashing Lamp E-08 connector X245 (pin A). Go to next test point. 19 Disconnect the Flasher Module A-05. Place a jumper wire across pins 1 and 11 of the Flasher Module A-05 connector X255. RH NASO. RH NASO Flashing Lamp E-09 illuminates. If good reading, replace the Flasher Module A-05. Short to ground on circuit 244 (PU) will blow Fuse #56.
Repair short to ground on circuit 244 (PU) between Flasher Module A-05 connector X255 (pin 11) and RH NASO Flashing Lamp E-08 connector X245 (pin A).