DISTRIBUTION SYSTEMS - LIGHTING SYSTEM Turn/hazard light Wiring harness - Testing (A.40.A.13.88 - G.40.A.20) AFX8010 9668 1 27/05/2004 A.40.A / 42 N° Test Point Expected Result Other Result (Possible Cause) 1 Place Hazard Switch S-25 in the "ON" position. Measure the voltage at LH NASO Flashing Lamp E-07, connector X242 terminal A. 0 to 12 volts If good reading, go to test point 2. Open circuit 243 (PU) between Flasher Module A-05 connector X255 (pin 10) and LH NASO Flashing Lamp E-07 connector X242 (pin A). Short to ground on circuit 243 (PU) between Flasher Module A-05 connector X255 (pin 10) and LH NASO Flashing Lamp E-07 connector X242 (pin A). Go to next test point.
2 Disconnect the LH NASO Flashing Lamp E-07. Measure resistance on circuit 679 (BK) between LH NASO Flashing Lamp E-07 connector X242 (pin B) and ground. Less than 1 ohms. If good reading, replace the bulb. Open circuit 679 (BK) between LH NASO Flashing Lamp E-07 connector X242 (pin B) and ground. 3 1 Place Hazard Switch S-25 in the ON position. Measure the voltage at RH NASO Flashing Lamp E-08, connector X245 terminal A. 0 to 12 volts If good reading, go to test point 2. Open circuit 244 (PU) between Flasher Module A-05 connector X255 (pin 11) and RH NASO Flashing Lamp E-08 connector X245 (pin A).
Short to ground on circuit 244 (PU) between Flasher Module A-05 connector X255 (pin 11) and RH NASO Flashing Lamp E-08 connector X245 (pin A). See Test B- Flasher Module A-05 step 18. Go to next test point. 4 Disconnect the RH NASO Flashing Lamp E-08. Measure resistance on circuit 680 (BK) between RH NASO Flashing Lamp E-08, connector X245 (pin B) and ground. Less than 1 ohms. If good reading, replace the bulb. Open circuit 680 (BK) between RH NASO Flashing Lamp E-08 connector X245 (pin B) and ground. 5 Place Hazard Switch S-25 in the ON position. Measure the voltage at LH Header Flashing Lamp E-01 connector X303 (pin A). 0 to12 volts If good reading, go to next test point.
Open circuit 613 (PU) between Flasher Module A-05 connector X255 (pin 3) and LH Header Flashing Lamp E-01 connector X303 (pin A). Short to ground on circuit 613 (PU) between Flasher Module A-05 connector X255 (pin 3) and LH Header Flashing Lamp E-01 connector X303 (pin A). See text B-Flasher Module Test step 8. Go to next test point. 6 Disconnect the LH Header Flashing Lamp E-01. Measure the resistance on circuit 775 (BK) and 776 (BK) between the LH Header Flasher Lamp E-01 connector X303 (pin B) and ground. Less than 1 ohms. If good reading, replace the bulb. Open in circuit 775 (BK) or 776 (BK) between LH Header Flashing Lamp E-01 connector X303 (pin B) and ground.