DISTRIBUTION SYSTEMS - LIGHTING SYSTEM 9668 1 27/05/2004 A.40.A / 43 N° Test Point Expected Result Other Result (Possible Cause) 7 Place Hazard Switch S-25 in the ON position. Measure the voltage at RH Header Flashing Lamp E-02 connector X304 (pin A). 0 to12 volts If good reading, go to next test point. Open circuit 618 (PU) between Flasher Module A-05 connector X255 (pin 4) and RH Header Flashing Lamp E-02 connector X304 (pin A). Short to ground on circuit 613 (PU) between Flasher Module A-05 connector X255 (pin 4) and RH Header Flashing Lamp E-02 connector X304 (pin A). See text B-Flasher Module Test step 8. Go to next test point. 8 Disconnect the RH Header Flashing Lamp E-02.
Measure the resistance on circuit 775 (BK) and 776 (BK) between the RH Header Flasher Lamp E-02 connector X304 (pin B) and ground. Less than 1 ohms. If good reading, replace the bulb. Open in circuit 775 (BK) or 776 (BK) between RH Header Flashing Lamp E-02 connector X304 (pin B) and ground. 9 Place Hazard Switch S-25 in the ON position. Measure the voltage at LH Front Hazard Lamp E-03 connector X160 (pin A). 0 to 12 volts If good reading, go to next test point. Open circuit 615 (PU) between Flasher Module A-05 connector X255 (pin 3) and LH Front Hazard Lamp E-03 connector X160 (pin A).
Short to ground on circuit 615 (PU) between Flasher Module A-05 (pin 3) and LH Front Hazard Lamp E-03 (pin A). See Test B-Flasher Module Test step 8. Go to next test point. 10 Disconnect the LH Front Hazard Lamp E-03. Measure the resistance on circuit 620 (BK) between LH Front Hazard Lamp E-03 connector X160 (pin C) and ground. Less than 1 ohms. If good reading, replace the hazard bulb of the LH Front Hazard Lamp E-03. Open in circuit 620 (BK) between LH Front Hazard Lamp E-03 connector X160 (pin C) and ground. 11 Place Hazard Switch S-25 in the ON position. Measure the voltage at RH Front Hazard Lamp E-04 connector X165 (pin A). 0 to 12 volts If good reading, go to next test point.
Open circuit 616 (PU) between Flasher Module A-05 connector X255 (pin 3) and RH Hazard Lamp E-04 connector X165 (pin A). Short to ground on circuit 616 (PU) between Flasher Module A-05 connector X255 (pin 4) and RH Front Hazard Lamp E-04 connector X165 (pin A). See Test B-Flasher Module Test step 8. Go to next test point. 12 Disconnect the RH Front Hazard Lamp E-04. Measure the resistance on circuit 621 (BK) between RH Front Hazard Lamp E-04 connector X165 (pin C) and ground. Less than 1 ohms. If good reading, replace the hazard bulb of the RH Front Hazard Lamp E-04 Open in circuit 621 (BK) between RH Front Hazard Lamp E-04 connector X165 (pin C) and ground.
13 Place Hazard Switch S-25 in the ON position. Measure the voltage at RH Rear Flashing Lamp E-06 connector X302 (pin 1). 0 to 12 volts If good reading, go to test point 2. Open circuit 619 (PU) between Flasher Module A-05 connector X255 (pin 3) and LH Rear Flashing Lamp E-05 connector X301 (pin 1). Short to ground on circuit 619 (PU) between Flasher Module A-05 connector X255 (pin 3) and LH Rear Flashing Lamp E-05 connector X301 (pin 1). See test B-Flasher Module Test step 8. Go to next test point.