Case IH AFX8010 — LIGHTING SYSTEM

DISTRIBUTION SYSTEMS - LIGHTING SYSTEM Turn/hazard light Hazard switch - Testing (A.40.A.13.90 - G.40.A.20) AFX8010 IMPORTANT: Do not use a self-powered test light for any of these tests. Use of a self powered test light can cause damage to components in this system. WARNING M980 - Before performing any of the electrical tests, be sure all operating controls are in neutral or park lock position. This will eliminate accidental movement of the machine or start-up of power driven equipment. 9668 1 27/05/2004 A.40.A / 44 N° Test Point Expected Result Other Result (Possible Cause) 14 Disconnect the LH Rear Flashing Lamp E-05.

Measure the resistance on circuit 634 (BK) between LH Rear Flashing Lamp E-05 connector X301 (pin 2) and ground. Less than 1 ohms. If good reading, replace the bulb. Open in circuit 634 (BK) between LH Rear Flashing Lamp E-05 connector X301 (pin 2) and ground. 15 Place Hazard Switch S-25 in the .ON. position. Measure the voltage at RH Rear Flashing Lamp E-06 connector X302 (pin 1). 0 to 12 volts If good reading, go to test point 2. Open circuit 622 (PU) between Flasher Module A-05 (pin 3) and RH Rear Flashing Lamp E-06 connector X302 (pin 1). Short to ground on circuit 622 (PU) between Flasher Module A-05 connector X255 (pin 3) and RH Rear Flashing Lamp E-06 connector X302 (pin 1).

See test B-Flasher Module Test step 8. Go to next test point. 16 Disconnect the RH Rear Flashing Lamp E-06. Measure the resistance on circuit 635 (BK) between RH Rear Flashing Lamp E-06 connector X302 (pin 2) and ground. Less than 1 ohms. If good reading, replace the bulb. Open in circuit 635 (BK) between RH Rear Flashing Lamp E-06 connector X302 (pin 2) and ground. N° Test Point Expected Result Other Result (Possible Cause) 1 Measure for 12 volts at Switch S-25 connector X259(pin 2). 12 volts If good reading, Go to test 3 Open circuit 40 (RD) or 54 (RD) between Hazard Switch S-25 connector X259 and Fuse F-56. Short to ground between Hazard Switch S-25 connector X259 (pin2) and Fuse F-56.

Go to next test point. 2 Flasher Module disconnected Measure for 12 volts at Hazard Switch S-25 connector X259 (pin 2). 12 volts If good reading, check Flasher Module. Short to ground in circuit 102 (RD) between flasher module A-05 connector X259 (pin 1) and fuse F-56. 3 Hazard Switch (S-25) in the "Closed" position. Measure for 12 volts at Hazard Switch S-25 connector X259 (pin 3). 12 volts If good reading, go to next test point. Hazard Switch S-25. 4 Measure for 12 volts at Hazard Switch (S-25) connector X259 (pin9). 12 volts If good reading, go to next test point. Hazard Switch S-25. 5 Hazard Switch (S-25) in the "Open" position.

Measure for resistance from Hazard Switch S-25 connector X259 (pin 9) to ground. Less than 1 ohms If good reading, Hazard Switch (S-25) is operating properly. Open circuit 220 (BK) or 219 (BK) between hazard switch S-25 X259 (pin 9) and ground.