Case IH AFX8010 — PRIMARY HYDRAULIC POWER SYSTEM

DISTRIBUTION SYSTEMS - PRIMARY HYDRAULIC POWER SYSTEM Regulated Pressure Valve Operation PFC is supplied at port (2) and is directed to the regulated valve assembly. All regulated functions are closed circuit operations, meaning they don’t require large volumes of oil BUT demand constant pressure. Since there is no real flow of oil through the circuits the pressure will stabilize at the current PFC working pressure which is to high. The regulating valve, through the pilot line (5), is monitoring the regulated pressure AFTER the valve.

As the regulated pressure increase the pressure is also directed to the non-spring end of the regulating valve and shuttles it against the spring, restricting the inflow of oil into the regulated circuit, maintaining the circuit pressure. Reference Material: Hydraulic Schematic Key Components: Regulated/Park Brake/Tow Valve Assembly Regulated Pressure The Regulating /Park Brake valve is teed into the hydraulic supply line from the PFC pump so when the PFC pump is operating, regardless of output pressure, the valve is receiving pump working pressure.

PFC pump low pressure stand-by may vary between 31--41 bar (450--600 PSI) so it is the job of the regulated valve to maintain a regulated pressure of 22--25 bar (320--360 PSI) for the complete regulated circuit. Regulated pressure may be tested at the test port (12). A.10.A / 39