Case IH AFX8010 — LIGHTING SYSTEM

DISTRIBUTION SYSTEMS - LIGHTING SYSTEM Beacon Relay - Testing (A.40.A.15.82 - G.40.A.20) AFX8010 Beacon Switch - Testing (A.40.A.15.83 - G.40.A.20) AFX8010 9668 1 27/05/2004 A.40.A / 56 E-31 LH Front Beacon Light E-32 RH Front Beacon Light E-33 Rear Beacon Light F-15 Service Sockets Fuse F-53 Beacon Light Fuse J-01 RH Front Service Socket J-02 LH Front Service Socket J-03 RH Side Service Socket J-04 LH Side Service Socket J-05 Engine Service Socket K-29 Beacon Light Relay S-41 Beacon Light Switch N° Test Point Expected Result Other Result (Possible Cause) 1 Place Key Switch S-02 in ON position. Close Beacon Light Switch S-41. Measure for 12 volts at Beacon Light Relay K-29 (pin 5).

12 volts If good reading, the relay is operating properly. Beacon Light Relay K-29. Adjacent circuits. Go to next test point. Go to test 2 2 Measure for 12 volts at Beacon Light Relay K-29 (pin 1). 12 volts If good reading, Go to test 3 Open or short to ground in circuit between Beacon Light Relay K-29 (pin 1) and CCM-2 connector X015 (pin J1-24). See Service Manual for testing of CCM. 3 Measure for 12 volts at Beacon Light Relay K-29 (pin 3). 12 volts If good reading, Go to test 4 Open in circuit 69 (RD) between Beacon Light Relay K-29 (pin 3) and Fuse #53. Short to ground on circuit 578 (PU) between Beacon Light Relay K-29 (pin 5) and Rear Beacon Light E-33 connector X247 (pin A).

A short will cause Fuse #53 to blow. 4 Disconnect the Beacon Light Relay K-29. Measure resistance on circuit 160 (BK) between Beacon Light Relay K-29 (pin 2) and ground. Less than 1 ohm. If good reading, Open circuit 160 (BK) between Beacon Light Relay K-29 (pin 2) and ground. N° Test Point Expected Result Other Result (Possible Cause) 1 Place Key Switch S-02 in ON position. Measure for 12 volts at Beacon Light Switch S-41 connector X130 (pin 2). 12 volts. If good reading, Go to test 2 Open circuit 172 (OR) or 45 (OR) between Beacon Light Switch S-41 connector X130 (pin 2) and Fuse #49. 2 Close Beacon Light Switch S-41. Measure for 12 volts at Beacon Light Switch S-41 connector X130 (pin 3).

12 volts If good reading, system OK. Beacon Light Switch. Short to ground on circuit 166 (YE) between Beacon Light Switch S-41 connector X130 (pin 3) and CCM-2 (pin J1-2) A short to ground will blow Fuse #49.