DISTRIBUTION SYSTEMS - LIGHTING SYSTEM Beacon Wiring harness - Testing (A.40.A.15.88 - G.40.A.20) AFX8010 Front work light Switch - Testing (A.40.A.16.83 - G.40.A.20) AFX8010 9668 1 27/05/2004 A.40.A / 57 N° Test Point Expected Result Other Result (Possible Cause) 1 Place Key Switch S-02 in ON position. Close Beacon Light Switch S-41. Measure for 12 volts at Beacon Light Relay K-29 (pin 5). 12 volts If good reading, Go to test 2 Perform Beacon Light Relay Test. 2 Measure the voltage at Rear Beacon Light E-33 connector X247 (pin A). 12 volts If good reading, Go to test 3 Open circuit 578 (PU) between Beacon Light Relay K-29 (pin 5) and Rear Beacon Light E-33 connector X247 (pin A).
3 Disconnect the Rear Beacon. Measure the resistance on circuit 623 (BK) between Rear Beacon Light E-33 connector X247 (pin B) and ground. Less than 1 ohm. If good reading, replace the Beacon Light bulb of the Rear Beacon E-33. Open circuit 623 (BK) between Rear Beacon Light E-33 connector X247 (pin B) and ground. 4 Place Key Switch S-02 in ON position. Close Beacon Light Switch S-41. Measure for 12 volts at Beacon Light Relay K-29 (pin 5). 12 volts If good reading, Go to test 5 Perform Beacon Light Relay Test. 5 Measure for 12 volts at LH Front Beacon Light E-31 connector X113 (pin A).
12 volts If good reading, Go to test 6 Open in circuit 579 (PU) or 663 (PU) between Beacon Light Relay K-29 (pin 5) and LH Front Beacon Light E-31 connector X113 (pin A). 6 Disconnect the LH Front Beacon E-31. Measure the resistance on circuit 666 (BK) between LH Front Beacon Light E-31 connector X113 (pin B) and ground. Less than 1 ohms If good reading, replace the Beacon Light bulb of the LH Front Beacon E-31. Open in circuit 666 (BK) between LH Front Beacon Light E-31 connector X113 (pin B) and ground. 7 Place Key Switch S-02 in ON position. Close Beacon Light Switch S-41. Measure for 12 volts at Beacon Light Relay K-29 (pin 5).
12 volts If good reading, Go to test 8 Perform Beacon Light Relay Test. 8 Measure for 12 volts at RH Front Beacon Light E-32 connector X119 (pin A). 12 volts If good reading, Go to test 9 Open in circuit 579 (PU) or 664 (PU) between Beacon Light Relay K-29 (pin 5) and RH Front Beacon Light E-32 connector X119 (pin A). 9 Disconnect the RH Front Beacon E-32. Measure the resistance on circuit 667 (BK) between RH Front Beacon Light E-32 connector X119 (pin B) and ground. Less than 1 ohms If good reading, replace the Beacon Light bulb of the RH Front Beacon E-32. Open in circuit 667 (BK) between RH Front Beacon Light E-32 connector X119 (pin B) and ground.
N° Test Point Expected Result Other Result (Possible Cause) 1 Place Key Switch S-02 in ON position. Measure for 12 volts at Work Light Switch S-43 connector X132 (pin 2). 12 volts. If good reading, Go to test 2 Open or short circuit 240 (OR) or 45 (OR) between Work Light Switch S-43 connector X132 (pin 2) and Fuse #49.