DISTRIBUTION SYSTEMS - LIGHTING SYSTEM Front work light Relay - Unidentified failure (A.40.A.16.82 - G.30.B.46) AFX8010 E0070-11 - Front Work Lights Context: Two relays are used to control the numerous work lights installed on the combine, but both relays are engaged using a single output signal from CCM1. Since the two relays are wired in parallel, it is possible to have a single relay fail, preventing certain lighting from coming on, without having a fault code indicated. This fault code will only occur if there is a short to ground anywhere on the supply wiring to the relays, or if there is an open circuit between the CCM1 module and the first relay (K-01).
An open circuit on one of the relay ground paths, or in the supply wiring to the K-21 relay will not cause this error to be displayed. Cause: The front work lights relay(s) (K-01, K-21) circuit is open, or shorted to ground. Possible failure modes: 1. Supply wiring damaged. 2. Bad relay(s). 3. Controller internal failure (internal regulator failure). Solution: 1. Enter the Universal Display Plus "DIAG" screen. Select the "LIGHTS" sort menu, and select "FRONT WORK LT". Change the drop-down list to "STATUS", and press the "OFF" button to change the circuit output to "ON". The "STATUS" screen should indicate "OK" if the circuit is working properly. A.
If the status screen indicates "ERROR", the circuit is open or shorted to ground. Continue with Step 2 . B. If the status screen indicates "OK", the circuit is working properly. Continue with Step 4 . 2. Key OFF. Remove the Cab Roof Work Lights relay K-01, and use a multimeter to check for continuity between relay base pin 1 and chassis ground. A. If there is not continuity to ground, continue with Step 3 . B. If there is continuity to ground, there is a short to ground in the cab main (CM) harness between connector X018 pin J1-11 and the work lights relays on one of the following wires:
- wire 190 white, connector X018 pin J1-11 to relay K01 pin 1 - wire 189 white, relay K01 pin 1 to relay K21 pin 1. Locate the short and repair. 3. Key OFF. Remove the Cab Roof Work Lights relay K-01. Use the Universal Display Plus "DIAG" screen controls to manually power the front work lights relays. Use a multimeter to check for 12V power between relay base pin 1 and chassis ground. A. If 12V is not present, there is an open circuit in the cab main (CM) harness between connector X018 pin J1-11 and relay base (K01) pin 1 wire 190 white. Locate the open and repair. B. If 12V is present, continue with Step 4 . 4.
Visually inspect the harness and connectors for damage, bent or dislocated pins, corroded terminals or broken wires. A. If no damage is found, erase the fault code and continue operation. 9668 1 27/05/2004 A.40.A / 64