DISTRIBUTION SYSTEMS - LIGHTING SYSTEM 9668 1 27/05/2004 A.40.A / 63 N° Test Point Expected Result Other Result (Possible Cause) 32 Place Key Switch S-02 in ON position. Close Work Light Switch S-43. Measure for 12 volts at Distance Work Lights Relay K-21 (pin 5). 12 volts. If good reading, Go to test 33 Perform the Work Light Switch Test. 33 Measure for 12 volts at LH Cab Inner Work Lights E-17 (pin A). 12 volts If good reading, Go to test 34 Open circuit 61 (PU) or 255 (PU) between Work Light Relay K-21 (pin 5) and LH Cab Inner Work Light E-17 connector X115 (pin A). 34 Disconnect the LH Cab Inner Work Light E-17.
Measure the resistance on circuit 261 (BK) between LH Cab Inner Work Light E-17 connector X115 (pin B) and ground. Less than 1 ohms. If good reading, replace the LH Cab Inner Work Light bulb. Open circuit 261 (BK) between LH Cab Inner Work Light E-17 connector X115 (pin B) and ground. 35 Place Key Switch S-02 in ON position. Close Work Light Switch S-43. Measure for 12 volts at Distance Work Lights Relay K-21 (pin 5). 12 volts. If good reading, go to next test point. Go to test 36 Perform the Work Light Switch Test. 36 Measure for 12 volts at RH Cab Inner Work Lights E-18 Relay (pin A).
12 volts If good reading, Go to test 37 Open circuit 61 (PU) or 256 (PU) between Work Light Relay K-21 (pin 5) and RH Cab Inner Work Light E-18 connector X117 (pin A). 37 Disconnect the RH Cab Inner Work Light E-18. Measure the resistance on circuit 265 (BK) between RH Cab Inner Work Light E-18 connector X117 (pin B) and ground. Less than 1 ohms. If good reading, replace the RH Cab Inner Work Light bulb. Open circuit 265 (BK) between RH Cab Inner Work Light E-18 connector X117 (pin B) and ground.