DISTRIBUTION SYSTEMS - LIGHTING SYSTEM 9668 1 27/05/2004 A.40.A / 62 N° Test Point Expected Result Other Result (Possible Cause) 19 Measure for 12 volts at LH Cab Outer Work Light E-15 connector X112 (pin A). 12 volts If good reading, Go to test 20 Fuse #6 Open circuit 58 (PU) or 251 (PU) between Fuse #6 and LH Cab Outer Work Light E-15 connector X112 (pin A). 20 Place Key Switch S-02 in ON position. Close Work Light Switch S-43. Measure for 12 volts at Cab Roof Work Lights Relay K-01 (pin 87). 12 volts. If good reading, Go to test 21 Perform Cab Roof Work Lights Relay Test. 21 Measure for 12 volts at Fuse #6, circuit 23 (OR).
12 volts If good reading, Go to test 22 Open circuit 23 (OR) between Fuse #6 and Cab Roof Work Lights Relay K-01 (pin 87). 22 Measure for 12 volts at LH Cab Mid Work Light E-19 connector X114 (pin A). 12 volts If good reading, Go to test 23 Fuse #6 Open circuit 58 (PU) or 252 (PU) between Fuse #6 and LH Cab Mid Work Light E-19 connector X114 (pin A). 23 Disconnect the LH Cab Mid Work Light E-19. Measure the resistance on circuit 260 (BK) between LH Cab Mid Work Light E-19 connector X114 (pin B) and ground. Less than 1 ohms. If good reading, replace the LH Cab Mid Work Light E-19 bulb. Open circuit 260 (BK) between LH Cab Mid Work Light E-19 connector X114 (pin B) and ground.
24 Place Key Switch S-02 in ON position. Close Work Light Switch S-43. Measure for 12 volts at Cab Roof Work Lights Relay K-01 (pin 87). 12 volts. If good reading, Go to test 25 Perform Cab Roof Work Lights Relay Test. 25 Measure for 12 volts at Fuse #7, circuit 88 (OR). 12 volts If good reading, Go to test 26 Open circuit 88 (OR) between Fuse #7 and Cab Roof Work Lights Relay K-01 (pin 87). 26 Measure for 12 volts at RH Cab Outer Work Light E-16 connector X120 (pin A). 12 volts If good reading, Go to test 27 Fuse #7 Open circuit 59 (PU) or 254 (PU) between Fuse #7 and RH Cab Outer Work Light E-16 connector X120 (pin A). 27 Disconnect the RH Cab Outer Work Light E-16.
Measure the resistance on circuit 264 (BK) between RH Cab Outer Work Light E-16 connector X120 (pin B) and ground. Less than 1 ohms. If good reading, replace the RH Cab Outer Work Light E-16 bulb. Open circuit 264 (BK) between RH Cab Outer Work Light E-16 connector X120 (pin B) and ground. 28 Place Key Switch S-02 in ON position. Close Work Light Switch S-43. Measure for 12 volts at Cab Roof Work Lights Relay K-01 (pin 87). 12 volts. If good reading, Go to test 29 Perform Cab Roof Work Lights Relay Test. 29 Measure for 12 volts at Fuse #7, circuit 88 (OR). 12 volts If good reading, Go to test 30 Open circuit 88 (OR) between Fuse #7 and Cab Roof Work Lights Relay K-01 (pin 87).
30 Measure for 12 volts at RH Cab Mid Work Light E-20 connector X118 (pin A). 12 volts If good reading, Go to test 31 Fuse #7 Open circuit 59 (PU) or 253 (PU) between Fuse #7 and RH Cab Mid Work Light E-20 connector X118 (pin A). 31 Disconnect the RH Cab Mid Work Light E-20. Measure the resistance on circuit 263 (BK) between RH Cab Mid Work Light E-20 connector X118 (pin B) and ground. Less than 1 ohms. If good reading, replace the RH Cab Mid Work Light bulb. Open circuit 263 (BK) between RH Cab Mid Work Light E-20 connector X118 (pin B) and ground.