DISTRIBUTION SYSTEMS - LIGHTING SYSTEM 9668 1 27/05/2004 A.40.A / 61 N° Test Point Expected Result Other Result (Possible Cause) 6 Disconnect the LH Lower Work Light E-23. Measure the resistance on circuit 654 (BK) between LH Lower Work Light E-23 connector X163 (pin B) and ground. Less than 1 ohms. Go to test 7 LH Lower Work Light bulb. Open in circuit 654 (BK) between LH Lower Work Light E-23 connector X163 (pin B) and ground. 7 Place Key Switch S-02 in ON position. Close Work Light Switch S-43. Measure for 12 volts at RH Lower Work Light Relay K-30 (pin 5). 12 volts. If good reading, Go to test 8 Perform Lower Work Lights Relay Test.
8 Measure for 12 volts at Lower Work Light E-24 connector X168 (pin A). 12 volts If good reading, Go to test 9 Open circuit 65 (PU) or 645 (PU) between Lower Work Lights Relay K-30 (pin 5) and RH Lower Work Light E-24 connector X168 (pin A). 9 Disconnect the RH Lower Work Light E-24. Measure the resistance on circuit 655 (BK) between RH Lower Work Light E-24 connector X168 (pin B) and ground. Less than 1 ohms. If good reading, replace the RH Lower Work Light bulb. Open in circuit 655 (BK) between RH Lower Work Light E-24 connector X168 (pin B) and ground. 10 Place Key Switch S-02 in .ON. position. Close Work light Switch S-43. Measure for 12 volts at Header Work Lights Relay K-22 (pin 5).
12 volts. If good reading, Go to test 11 Perform Header Work Lights Relay Test. 11 Go to test 12 12 Measure for 12 volts at LH Header Light E-21 connector X162 (pin A). 12 volts If good reading, Go to test 13 Open circuit 63 (PU) or 257 (PU) between Header Work Lights Relay K-22 (pin 5) and LH Header Light E-21 connector X162 (pin A). 13 Disconnect the LH Header Light E-21. Measure the resistance on circuit 267 (BK) between LH Header Light E-21 connector X162 (pin B) and ground. Less than 1 ohms. If good reading, replace the LH Header Light bulb. Open circuit 267 (BK) between LH Header Light E-21 connector X162 (pin B) and ground. 14 Place Key Switch S-02 in .ON. position.
Close Work light Switch S-43. Measure for 12 volts at Header Work Lights Relay K-22 (pin 5). 12 volts. If good reading, Go to test 15 Perform Header Work Lights Relay Test. 15 Measure for 12 volts at RH Header Light E-22 connector X167 (pin A). 12 volts If good reading, Go to test 16 Open circuit 63 (PU) or 258 (PU) between Header Work Lights Relay K-22 (pin 5) and RH Header Light E-22 connector X167 (pin A). 16 Disconnect the RH Header Light E-22. Measure the resistance on circuit 268 (BK) between RH Header Light E-22 connector X167 (pin B) and ground. Less than 1 ohms. If good reading, replace the RH Header Light bulb.
Go to test 17 Open circuit 268 (BK) between RH Header Light E-22 connector X167 (pin B) and ground. 17 Place Key Switch S-02 in ON position. Close Work Light Switch S-43. Measure for 12 volts at Cab Roof Work Lights Relay K-01 (pin 87). 12 volts. If good reading, Go to test 18 Perform Cab Roof Work Lights Relay Test. 18 Measure for 12 volts at Fuse #6, circuit 23 (OR). 12 volts If good reading, Go to test 19 Open circuit 23 (OR) between Fuse #6 and Cab Roof Work Lights Relay K-01 (pin 87).