DISTRIBUTION SYSTEMS - LIGHTING SYSTEM Side work light Relay - Testing (A.40.A.18.82 - G.40.A.20) AFX8010 9668 1 27/05/2004 A.40.A / 75 E-15 LH Cab Outer Work Light E-16 RH Cab Outer Work Light E-17 LH Cab Inner Work Light E-18 RH Cab Inner Work Light E-27 LH Rear Work Light E-28 RH Rear Work Light F-06 LH Outer Road/Work Lights Fuse F-07 RH Outer Road/Work Lights Fuse F-29 Inner Road/Work Lights Fuse F-31 Outer Road/Work Lights Fuse F-55 Rear Work Lights Fuse K-01 Outer Road/Work Lights Relay K-21 Inner Road Lights Relay K-27 Inner Work Lights Relay K-31 Rear Work Lights Relay N° Test Point Expected Result Other Result (Possible Cause) 1 Remove Timed Side Work Light Relay K-34.
Cycle LH Door Switch. Measure for 12 volts at Timed Side Work Light Relay K-34 (pin 1). 12 volts If good reading, Go to test 2 Open or short to ground in circuit 969 (PU) between Time Delay Module K-20 (pin 87) and Timed Side Work Light Relay K-34 (pin 1). Time Delay Module K-20. See Interior Lights section for testing. 2 Measure for 12 volts at LH Side Work Light Relay (pin 3). 12 volts If good reading, Go to test 3 Open in circuit 73 (RD) between Timed Side Work Light Relay K-34 (pin 3) and Fuse #50. Short to ground on circuit 76 (PU) 165 (PU) or 72 (PU) between Timed Side Work Light Relay K-34 (pin 5) and Side Work Lights E-25 and E-26 connector X297 and X298 (pin A).
A short will cause Fuse #50 to blow. 3 Disconnect the Timed Side Work Light Relay K-34. Measure the resistance on circuit 161 (BK) between Timed Side Work Light Relay K-34 (pin 2) and ground. Less than 1 ohms If good reading, replace Timed Side Work Light Relay K-34. Open in circuit 161 (BK) between Timed Side Work Light Relay K-34 (pin 2) and ground. 4 Place Key Switch S-02 in ON position. Close Work Light Switch S-43. Measure for 12 volts at Side Work Light Relay K-35 (pin 5). 12 volts If good reading, the relay is operating properly. Side Work Light Relay K-35. Adjacent circuits. Go to test 5 5 Partially remove Side Work Light Relay K-35.
Measure for 12 volts at LH Side Work Light Relay (pin 2). 12 volts If good reading, Go to test 6 Open or short to ground in circuit 180 (WH) between Side Work Light Relay K-35 (pin 1) and CCM-1 connector X018 (pin J1-24). See Service Manual for testing of CCM. 6 Measure for 12 volts at Side Work Light Relay K-35 (pin 3). 12 volts If good reading, Go to test 7 Open circuit 71 (RD) or 73 (RD) between Side Work Light Relay K-35 (pin 3) and Fuse #50. Short to ground on circuit 72 (PU), 165 (PU) or 76 (PU) between Side Work Light Relay K-35 (pin 5) and Side Work Lights E-25 and E-26 connectors X297 and X298 (pin A). A short will cause Fuse #50 to blow.
7 Disconnect the Timed Side Work Light Relay K-34. Measure the resistance on circuit 161 (BK) between Timed Side Work Light Relay K-34 (pin 2) and ground. Less than 1 ohms Open in circuit 161 (BK) between Side Work Light Relay K-35 (pin 2) and ground.