DISTRIBUTION SYSTEMS - LIGHTING SYSTEM Under shield service light Switch - Testing (A.40.A.19.83 - G.40.A.20) AFX8010 Under shield service light Wiring harness - Testing (A.40.A.19.88 - G.40.A.20) AFX8010 IMPORTANT: Do not use a self-powered test light for any of these tests. Use of a self powered test light can cause damage to components in this system. WARNING M980 - Before performing any of the electrical tests, be sure all operating controls are in neutral or park lock position. This will eliminate accidental movement of the machine or start-up of power driven equipment.
9668 1 27/05/2004 A.40.A / 79 E-25 LH Side Work Light E-26 RH Side Work Light E-29 Unload Tube Light E-37 Sieve Light Front E-59 Sieve Light Rear F-14 Service Lights Fuse F-50 Side / Tube Lights Fuse K-32 Unload Tube Light Relay K-34 Timed Side Work Light Relay K-35 Side Work Light Relay S-54 Sieve Light Switch N° Test Point Expected Result Other Result (Possible Cause) 1 Place LH Undershield Light Switch S-63 in ON position. Measure for 12 volts at LH Undershield Light Switch S-63 connector X339 (pin 2). 12 volts If good reading, the wiring has good continuity, Go to test 2 Open circuit 1214 (RD) between LH Undershield Light Switch S-63 connector X339 (pin 2) and Fuse #34.
2 Close LH Undershield Light Switch S-63. Measure for 12 volts at LH Undershield Light Switch S-63. connector X339 (pin 3) and ground. 12 volts If good reading, system OK. LH Undershield Light Switch S-63. Short to ground on circuit 2014 (BK) between LH Undershield Light Switch S-63 connector X339 (pin 3) and ground. A short to ground will blow Fuse #34. 3 Place RH Undershield Light Switch S-65 in ON position. 12 volts at RH Undershield Light Switch S-65 connector X341 (pin 2). 12 volts If good reading, the wiring has good continuity, Go to test 4 Open circuit 1215 (RD) or 2008 (RD) between RH Undershield Light Switch S-65 connector X341 (pin 2) and Fuse #34.
4 Close RH Undershield Light Switch S-65. Measure for 12 volts at RH Undershield Light Switch S-65. connector X341 (pin 3) and ground. 12 volts If good reading, system OK. RH Undershield Light Switch S-65. Short to ground on circuit 2015 or 2008 (RD) between RH Undershield Light Switch S-65 connector X341 (pin 3) and ground. A short to ground will blow Fuse #34. N° Test Point Expected Result Other Result (Possible Cause) 1 Under Shield Light Switch (S-63) in the ON position. Measure voltage at LH Front Shield Light (E-42) connector X345 (pin A). 12 volts Open circuit 2005 (PU) or 2004 (PU). 2 Under Shield Light Switch (S-63) in the ON position.
Measure voltage at LH Rear Shield Light (E-43) connector X346 (pin A). 12 volts Open circuit 2006 (PU) or 2004 (PU). 3 Under Shield Light Switch (S-63) in the ON position. Measure voltage at RH Front Shield Light (E-44) connector X347 (pin A). 12 volts Open circuit 2012 (PU) or 2004 (PU).