Case IH AFX8010 — LIGHTING SYSTEM

DISTRIBUTION SYSTEMS - LIGHTING SYSTEM Cleaning shoe service light Switch - Testing (A.40.A.20.83 - G.40.A.20) AFX8010 Cleaning shoe service light Wiring harness - Testing (A.40.A.20.88 - G.40.A.20) AFX8010 9668 1 27/05/2004 A.40.A / 80 N° Test Point Expected Result Other Result (Possible Cause) 4 Under Shield Light Switch (S-63) in the ON position. Measure voltage at RH Rear Shield Light (E-45) connector X348 (pin A). 12 volts Open circuit 2011 (PU) or 2004 (PU). 5 Disconnect LH Front Shield Light (E-42) from connector X345. Measure electrical resistance at connector X345 (pin B). Less than 1 ohms If good reading, replace the LH Front Shield Light bulb. Open circuit 2017 (BK) or 1247 (BK).

Repair or Replace as wiring necessary. 6 Disconnect LH Rear Shield Light (E-43) from connector X346. Measure electrical resistance at connector X346 (pin B). Less than 1 ohms If good reading, replace the LH Rear Shield Light bulb. Open circuit 2016 (BK) or 1247 (BK). Repair or Replace as wiring necessary. 7 Disconnect RH Front Shield Light (E-44) from connector X347. Measure electrical resistance at connector X347 (pin B). Less than 1 ohms If good reading, replace the RH Front Shield Light bulb. Open circuit 2018 (BK) or 1247 (BK). Repair or Replace as wiring necessary. 8 Disconnect RH Rear Shield Light (E-45) from connector X348. Measure electrical resistance at connector X348 (pin B).

Less than 1 ohms If good reading, replace the RH Rear Shield Light bulb. Open circuit 2019 (BK) or 1247 (BK). Repair or Replace as wiring necessary. N° Test Point Expected Result Other Result (Possible Cause) 1 Measure the voltage at Sieve Light Switch S-54 connector X237 (pin 2). 12 volts If good reading, Go to test 2 Blown Fuse #14 Open circuit 604 (OR) between Sieve Light Switch S-54 connector X237 (pin 2) and Fuse #14. Short to ground on circuit 604 (OR) between Sieve Light Switch S-54 connector X237 (pin 2) and Fuse #14. A short to ground will blow the Fuse #14. 2 Close Sieve Light Switch S-54. Measure for 12 volts at Sieve Light Switch S-54 connector X237 (pin 3).

12 volts IIf good reading, switch is working properly. Sieve Light Switch S-54 Short to ground in circuit 610 (PU between Sieve Light Switch S-54 connector X237 (pin 3) and Sieve Light E-37 connector X234 (pin A). A short to ground will blow the Fuse #14. N° Test Point Expected Result Other Result (Possible Cause) 1 Close Sieve Light Switch S-54. Measure for 12 volts at Sieve Light Switch S-54 connector X237 pin 3). 12 volts. If good reading, Go to test 2 Perform Sieve Light Switch Test.