Case IH AFX8010 — PRIMARY HYDRAULIC POWER SYSTEM

DISTRIBUTION SYSTEMS - PRIMARY HYDRAULIC POWER SYSTEM Filtration 2. Filter Base 4. Restrictions Indicator 5. Filter By-Pass Port The control pressure filter is on the supply side of the control pressure circuits, the filter is a pressure filter. The filter base incorporates a filter restriction sensor (4) that monitors the condition of the filter element. If the restriction increases above 2.76 bar (40 PSID) differential pressure the sensor will CLOSE to create a signal to the Universal Display Plus monitor for operator warning. The filter base incorporates a filter by-pass valve that will open at 3.45 bar (50 PSID) differential pressure to prevent over pressuring the filter.

Since the flow is supplying the hydrostatic pumps and motor the filter by-pass does NOT permit dirty oil to flow through the filter base down stream. The filter base directs the by-pass out port (5) to the return manifold. The sensor is set to activate prior to the by-pass valve opening. M207103 M208003 B 28 A.10.A / 46