DISTRIBUTION SYSTEMS - PRIMARY HYDRAULIC POWER SYSTEM Control Pressure Schematic The control circuit pump is used to supply the ground, rotor, and feeder drive hydrostatics and their associated control valves, the unloading auger and chopper/separator clutches. Excess oil is bypassed through the control valve and is returned to the return manifold. All the oil from the return manifold is directed to the lubrication pump inlet, then to the control pump inlet. These two pumps will consume all the return flow and still need more oil to pump. The control circuit pump will receive the remaining oil from the PTO gearbox reservoir/sump. 2.
The filter base monitors the filter restriction and by-pass the oil if needed and directs the oil to the Control/Lube Pressure regulating valve. 3. The control pressure is regulated by an adjustable relief valve and directed out to the distribution manifold. All excess oil that is bleed off by the regulating valve is directed to the return manifold and sent to the PTO gearbox and charge the lubrication and control circuit pump. 4. The distribution manifold contains a pressure sensor to monitor the Control Pressure, sending a signal to the Universal Display Plus monitor for operator information. 1.
The control circuit pump pulls oil from the return manifold and the PTO gearbox and directs it to the control circuit filter base A.10.A / 49