Case IH AFX8010 — PRIMARY HYDRAULIC POWER SYSTEM

DISTRIBUTION SYSTEMS - PRIMARY HYDRAULIC POWER SYSTEM Electrical Monitoring Circuits The system uses two sensors to monitor the systems operations. Key Components: Control Pressure Sensor B--35, CCM2 Location: In the control pressure manifold at the feeder drive pump. Control Pressure Filter Restrictions Switch Reference Material: Electrical schematic frames #10 The control pressure sensor is used to monitor the control pressure. The sensor provides a constant pressure reading to the CCM2. The CCM2 places a message on the data bus for the Universal Display Plus monitor to display and provides a warning if the pressure should drop, providing a warning to the operator. Key Components:

Filter Restrictions Switch S--34, CCM1 The filter restriction switch is used to monitor the condition of the filter. The switch is a N/O switch. When the pressure differential exceeds the specifications the switch piston will shuttle over connecting the power wire to the ground. A 5V power supply from the CCM2 connector X016 terminal J2--31 is directed to the B terminal of the sensor and a return wire from the A terminal is directed back to the CCM2 connector X016 terminal J2--14. The sensors C wire provides the pressure signal to the CCM2 connector X016 terminal J2--19. When the pressure is normal, a signal voltage above 3V is normal.

The reading may be monitor on the Universal Display Plus monitor diagnostic screen. Power is supplied from the CCM1 connector X019 terminal J2--35 to the B terminal on the switch. The A terminal is directed to chassis ground point (1). Control Pressure Sensor Reference Material: Electrical schematic frames #10, #27 A.10.A / 50