Case IH AFX8010 — ELECTRONIC SYSTEM

DISTRIBUTION SYSTEMS - ELECTRONIC SYSTEM B. If there is continuity to ground, there is an open circuit in the precision farming (PF) harness between connector X442 pin 2 and connector X222 pin 2 wire 564 black. Locate the open and repair. 7. Turn the key switch to the ON position. Use the Universal Display Plus "DIAG" screen controls to manually power the bypass unit engage output. Use a multimeter to check for 12 volts between connector X222 pin 4 and chassis ground. A. If 12 volts is not present, continue with step 8 . B. If 12 volts is found, continue with Step 6 . 8. Turn the key switch to the ON position.

Use the Universal Display Plus "DIAG" screen controls to manually power the bypass unit engage output. Use a multimeter to check for 12 volts between connector X442 pin 4 and chassis ground. A. If 12 volts is not present, there is an open circuit in the expansion (EX) harness between connector X442 pin 4 and connector X013 pin J2-13 wire 837 white. Locate the open and repair. B. If 12 volts is found, there is an open circuit in the precision farming (PF) harness between connector X442 and connector X222 wire 837 white. Locate the open and repair. 9. Visually inspect the harness and connector for damage, bent or dislocated pins, corroded terminals or broken wires. A.

If no damage is found, erase the fault code and continue operation. 9669 1 27/05/2004 A.50.A / 1 20