DISTRIBUTION SYSTEMS - PRIMARY HYDRAULIC POWER SYSTEM HYDRAULIC SYSTEM TESTING PROCEDURES When diagnosing a hydraulic system problem, check the electrical circuits first by verifying that the proper solenoids are activated at the correct time. This will isolate hydraulic problems from electrical problems. CAUTION Hydraulic oil escaping under pressure can have enough force to penetrate the skin. Hydraulic oil may also infect a minor cut or opening in the skin. If injured by escaping oil, see a doctor at once. Serious infection or reaction can result if medical treatment is not given immediately.
Make sure all connections are tight and that hoses and lines are in good condition before applying pressure to the system. Relieve all pressure before disconnecting the lines or performing other work on the hydraulic system. BEFORE STARTING ANY TESTS: Be sure all oil filters are clean and the reservoir is full of clean oil. Check the tension and condition of the drive belt. Verify the pump is being driven. Check the high and low idle settings of the engine. Inspect the hydraulic system for leaks and replace hoses and tubing that show damage or wear. All tests are to be conducted with an oil temperature of at least 37 o C (100 o F).
To find a leak under pressure, use a small piece of cardboard or wood, never use hands. Clean all connecting points thoroughly before disconnecting any lines. Cap all disconnected lines that are not used to maintain system cleanliness. A.10.A / 57