POWER PRODUCTION - ENGINE UNIVERSAL DISPLAY PLUS FAULT CODE 0400.2 BOOST AIR TEMPERATURE, DATA INCORRECT 0400.3 BOOST AIR TEMPERATURE, SHORTED TO HIGH SOURCE 0400.4 BOOST AIR TEMPERATURE, SHORTED TO LOW SOURCE Cause: Signal range outside threshold limits Signal not plausible or intermittent fault Effect on Engine: Engine enabled -- no restriction on fuel or speed Possible failure modes: 1. Faulty sensor 2. Faulty connector or wiring Solution: 1. Harness connector fault A. Inspect the harness connector X374 onto the air temp sensor B54. Ensure that the connector is not damaged, the pins are correctly located in the connector body and that it is a tight fit onto the sensor. B.
If the harness connector is okay continue with step 3. 2. Air Temp Sensor B54 Fault To test the sensor measure the resistance across pins 1 and 2 of the sensor. The resistance will vary according to the temperature detailed in the table below: Wiring harness -- Electrical schematic frame 03 (A.30.A.88 -- C.20.E.03) B.20.A / 103