POWER PRODUCTION - ENGINE C. If the sensor is to specification continue with step 3. 3. Wiring faulty A. Check the wiring from the the engine ECU to the sensor connector. With the keystart ON, +5V should be measured on pin 1 of sensor connector X374 (+5V common line). If ZERO volts is indicated check for an Open Circuit or Short to ground back to the engine ECU , connector X192, pin 21. Trace fault and repair wiring as required. If wiring to pin 1 is okay continue with step B. B. With the keystart OFF, continuity to ground should be indicated on pin 2 of sensor connector X374 (ground common line).
If no ground is indicated, check for an Open circuit back to the engine ECU, connector X192, pin 4. Trace fault and repair wiring as required. With the keystart ON, check pin 2 for a short to +12V. If +12V is indicated trace fault and repair wiring to pin 2.
B.20.A / 104 Resistance in Ω Temperature in °C Minimum Nominal Maximum --40 ± 1 38313 45313 53103 --30 ± 1 22362 26114 30258 --20 ± 1 13402 15462 17718 --10 ± 1 8244 9397 10661 0 ± 1 5227 5896 6623 10 ± 1 3396 3792 4222 20 ± 1 2262 2500 2760 30 ± 1 1555 1707 1867 40 ± 1 1080 1175 1277 50 ± 1 771 834 900 60 ± 1 555 595 639 70 ± 1 408 435 465 80 ± 1 304 322 342 90 ± 1 231 243 257 100 ± 1 178 186 196 110 ± 1 137 144 152 120 ± 1 106 112 119 130 ± 1 84 89 95