POWER PRODUCTION - ENGINE 5. Remove connector X193 from the ECU, and check the voltage at connector X193 pin 3 or 4 ; it should be approx. 12 volts. A. If the voltage is less than 12 volts, there is excessive resistance in the engine (EN) harness between connector X010 pin 28 and connector X193 pin 3 or 4 in one of the following wires: Wire 809 white, connector X010 pin 28 to harness splice Wire 810 white, harness splice to connector X193 pin 3 Wire 811 white, harness splice to connector X193 pin 4 Inspect the harness and connectors and repair. B. If the voltage is approx. 12 volts, continue with step 6. 6. Remove the jumper wire from the K14 relay mounting socket, and install the K14 relay.
Remove connector X211 from the K39 grid heater relay, and check for voltage at connector X211 pin 1 wire 818 white ; it should be approx. 12 volts. A. If the voltage is less than 12 volts, there is a fault in the K14 relay. Replace the relay. B. If the voltage is approx. 12 volts, erase the fault code and continue operation. 7. Remove connector X211 from the K39 grid heater relay, and monitor the voltage at connector X211 pin 1 wire 818 white . Have an operator start the engine and run the engine to high idle and back to low idle. The voltage should not exceed 15 volts. A. If the voltage exceeds 15 volts, there is a fault with the alternator.
Repair the alternator to correct the cause of overcharging. B. If the voltage remains under 15 volts, erase the fault code and continue operation. Wiring harness -- Electrical schematic frame 02 (A.30.A.88 -- C.20.E.02) 24 13 1 X192 X211 X192 & X193 X193 10010906 B.20.A / 130