POWER PRODUCTION - AIR INTAKE SYSTEM 6. To prevent damage to the element when cleaning with compressed air, take the following precautions: 1) Maximum air pressure should not exceed 5 Bar or 72.5 psi. 2) Move the nozzle up and down when rotating the element. 3) Keep the nozzle at least 25 mm (1" inch.) from the pleated paper. NOTE: To keep the interval acceptable it is highly recommended to clean the element with compressed air. 7. If the element is soiled with oil or soot, it is possible to dip the filter in and out of a bucket containing 75 grams (0.165 lbs.) of non-sudsey detergent and 10 liters (2.6 US gal.) and lukewarm water.
Once the filter appears to be clean rinse the filter off lightly with clean water to remove the soap. NOTE: Do not allow water to get into the inside of the filter. Always keep the open end up while dipping. NOTE: Do not use high pressure water to clean the filter when rinsing. Use only low pressure tap water. NOTE: Never use Gasoline or Diesel fuel to clean the Air filter element. 8. Every time the element is cleaned, it should be examined for holes and cracks by holding an electric light bulb inside the element and looking through it. If any damage is noted, discard the element and fit a new one. 9. Replace the element after 3 cleanings or once a year, whichever comes first. 10.
When fitting, make sure the element is seated properly and the sealing is in good condition. 11. A safety element is fitted as an additional security to prevent dust from entering the engine when replacing the standard element. The safety element should normally not be cleaned. Replace the safety element when the primary element is changed. 20030147 4 9673 1 27/05/2004 B.30.A / 12