Case IH AFX8010 — AIR INTAKE SYSTEM

POWER PRODUCTION - AIR INTAKE SYSTEM 6. Disconnect the engine (EN) harness from the main frame (MF) harness at connector X010 . Use a multimeter to check for voltage on the main frame (MF) harness end of connector X010 pin 8. A. If no voltage is found, there is a short in the engine (EN) harness between connector X202 pin 2 and connector X010 pin 8 wire 864 yellow or 420 yellow. Locate the short and repair. B. If high (> 5.5 volts ) voltage is found, there is a short in the main frame (MF) harness between connector X010 pin 8 and connector X016 pin J2-29 wire 420 yellow. Locate the short and repair. 7. Operate the machine while monitoring Universal Display Plus "DIAG" screen. A.

If no high out of range readings are indicated, erase the fault code and continue operation. 9673 1 27/05/2004 B.30.A / 20