Yanmar — Yanmar Diesel Inboard Shop Manual for One, Two, and Three Cylinder Engines

178 CHA PTER EIG HT Press ur e r eli ef valve spring U pper sea lin g gasket Lowe r seati ng gasket Upper sealing surlace cooling systems and requires the same type of pressure tester. 1. Remove the pressure fill cap from the heat exchanger. See Fi gur e Jl , typical. 2. Wash the cap with clean water to remove any debris or deposits from its sealing su rf aces. 3. Check the gasket. if so equipped, and rubber seal on the cap for cuts, cracks. tears or deterioration. See Figu re 32. Replace the cap if the seal is damaged. Make sure the lockin g tabs on the cap are not damaged or bent. 4.

Dip the cap in water and attac h it to a cooling system pres sure lester, using the adapters supplied with the tester. Sec F i ~ u r e 33. 5. Pump the pressure to 13 psi (90 kPa). If the cap fails to hold pressure for )0 seconds without dropping under 11 psi (76 kPa). rep lace it. 6. Inspect the filler neck scat and sealing surface (F igure 32) for nicks, dents , distortion or contamination. Wipe the sca ling surface with a clean cloth to remove any rust or dirt. Make sure the locking cams are not bent or damaged . 7. Check coolant level. It should be within I in. (25.4 mm) ofthc filler neck. Top ofT if necessary, ~ Sa fety sto p -:::::::: ±:: ..--:::

01 Cam l oc king su rlace :;:::::..---........--- \ 8. Connect the cooling system pressure tester to the filler neck and pressurize the system to 15 psi (104 kPa). If pressure does not hold constant for at least ""'· 0 minutes, check all hoses. gaskets, dra in plugs, dra in valves and other potential leak points for leakage. Listen for a hissing or bubbling sound while the system is under pressure. 9. If no leaks are f ound . disconnect the seawater outlet hose from the heat exc hanger (Figure 34). Repressurize the system 10 IS psi (104 kPa) and note the outlet connec- tion on the heat exchanger.

lf water flows from the con - nection, air bubbles are visible in the water or a bubbling or hissing noise is heard. there is probably a leak between the fresh and seawater sections within the heal exchanger.