188 CHAPTER NINE Battery At 80° F to the alternator mounting bracket or an- other good engine ground and not the bat- tery itself. Make connections in numerical order (disconnect in reverse order 4-3-2-1) 2. Check that all jumper cables are out of the way ofmov- ing parts on both engines. 3. Start the engine with the good battery and run at a mod- erate speed. 4. Start the engine with the discharged battery. Once it starts, run it at a moderate speed. CAUTION Racing the engine may damage the electri- cal system. Discharged battery 5. Remove the jumper cables in the exact reverse order shown in Figure 11. Begin at point 4, then disconnect at points 3, 2 and 1. on the battery.

Check cable condition and terminal con- nections periodically. Battery Cables ELECTRICAL PROTECTION Poor terminal connections will cause excessive resis- tance. Defective cable insulation can cause partial short circuits. Both conditions may result in an abnormal volt- age drop in the starter motor cable. When this happens, the resulting hard-start condition will place further strain Some electrical systems are equipped with a battery cutoff switch connected between the positive terminal of the battery and the starter solenoid. The switch provides a means to cut off all circuits from the battery in case of fire