ELECTRICAL SYSTEM 187 warm up to room temperature before charging. The bat- tery does not have to be removed from the boat before charging, but it is a recommended procedure since a charging battery gives off highly explosive hydrogen gas. In many boats, the area around the battery is not well ven- tilated and the gas may remain in the area for several hours after the charging procedure has been completed. Sparks or flames occurring near the battery can cause it to explode, spraying battery acid over a wide area. Disconnect the negative battery cable first, then the positive battery cable. Make sure the electrolyte is full.
Remove the vent caps and place a folded paper towel over the vent openings to absorb any electrolyte that may splat- ter as the battery charges. Connect the charger to the battery; negative to negative, positive to positive. If the charger output is variable, select a 10-12 amp setting. Set the voltage selector to 12 volts and plug the charger in. Once the battery starts to accept a charge, reduce the charge rate to a level that will prevent excessive gassing. The length of time required to recharge a battery de- pends upon its rating, state of charge and temperature. Generally speaking, the current input time should equal the battery amp-hour rating.
For example, a 45 AH battery will require a 9-amp charging rate for five hours (9 x 5 = 45) or a 15-amp charging rate for three hours (15 x 3 = 45). Check charging progress with the hydrometer. DEAD NEEDS FULLY CHARGING CHARGED ,lOG 1210 112. Jump Starting Weight If the battery becomes discharged, it is possible to start and run the engine by jump starting it from another bat- tery. Before jump starting a battery when temperatures are 32° F (0° C) or lower, check the condition of the electro- lyte. If it is not visible or if it appears to be frozen, do not attempt to jump start the battery, as the battery may ex- plode or rupture. For every 10° below 80° F (27° C), subtract 0.004.
WARNING Use extreme caution when connecting a booster battery to one that is discharged to avoidpersonal injury or damage to the sys- tem. Charging Maintain batteries used for starting in a good state of charge. Check the battery with a voltmeter as shown in Figure 10. Recharge any battery that cannot deliver at least 9.6 volts under a starting load. Ifrecharging does not bring it up to strength or if it does not hold the charge, re- place the battery. A cold battery will not accept a charge readily. If the temperature is below 40° F (5° C), allow the battery to 1. Connect the jumper cables in the order and sequence shown in Figure 11.
WARNING An electrical arc may occur when the final connection is made. This could cause an ex- plosion if it occurs near the battery. For this reason, thefinal connection should be made