186 CHAPTER NINE BATTERY ELECTROLYTE LEVEL Vent cap .... _~ ... , Bottom of vent well Maximum liquid level -, ; Plates Electrolyte must be 3/16 in. above plates 10. Tighten the battery cable connections to 9 ft.-lb. (12 Nom). Overtightening the connections can cause damage to the battery case. Coat the connections with petroleum jelly, or a light mineral grease. Aerosol anti-corrosion sprays can also be used. NOTE Do not overfill the battery cells in Step 11. The electrolyte expands due to heat from charging and may overflow if the level is more than 1/4 in. (6 mm) above the battery plates. the cells. Run the engine or charge the bat- tery for 15-20 minutes prior to testing.

Draw enough electrolyte to float the weighted float inside the hydrometer. Whenusinga temperature-compensated hydrometer, release the electrolyte and repeat this process several times to make sure the thermometer has adjusted to the electrolyte temperature before taking the reading. 11. Remove the filler caps and check the electrolyte level. The electrolyte should cover the battery plates by at least 3/16 in. (4.8 mm). See Figure 7. Top off with dis- tilled water to the bottom of the fill ring in each cell, if necessary. Hold the hydrometer vertically and note the number aligned with the surface ofthe electrolyte (Figure 9). This is the specific gravity for the cell.

Return the electrolyte to the cell from which it came. Battery Testing The specific gravity of the electrolyte in each battery cell is an excellent indicator of that cell's condition. A fully charged cell will read 1.260 or more at 80° F (27° C). If the cells test below 1.220, the battery must be re- charged. Charging is also necessary if the specific gravity varies more than 50 points from cell to cell. Hydrometer testing is the best way to check battery condition. Use a hydrometer with numbered graduations from 1.100-1.300 rather than one with color-coded bands. To use the hydrometer, squeeze the rubber ball, insert the tip in a cell and release the ball (Figure 8).

NOTE Do not attempt to test a battery with a hy- drometer immediately after adding water to NOTE If a temperature-compensated hydrometer is not used, add 0.004 to the specific gravity reading for every ]00 above 80° F (27° C). I.