SERIES 60 EGR TECHNICIAN'S GUIDE Failure Mode : SID 147, FMI 7 — VNT Vanes Not Responding (EGR Mode) Indicates : EGR flow requested by DDEC and excessive EGR flow detected. SID 147, FMI 7 will be set by the ECM if, the signal from the Delta P sensor and EGR temperature sensor indicate EGR flow is above a desired flow for a period greater than 50 seconds. Response : The CEL will be illuminated and the system will be forced into “Boost Mode” (EGR is Disabled) for the remainder of the ignition cycle. Possible Causes : VNT vanes/actuator — mechanical failure High exhaust restriction Defective Delta P sensor EGR valve — mechanical failure Failure Mode :
SID 147, FMI 14 — EGR Flow Too Low Indicates : EGR flow requested by DDEC and insufficient EGR flow detected. SID 147, FMI 14 will be set by the ECM if, the signal from the Delta P sensor and EGR temperature sensor indicate EGR flow is below a desired flow for a period greater than 50 seconds. Response : The CEL will illuminate and a fault message will be generated. Possible Causes :
VNT vanes/actuator — mechanical failure EGR cooler restriction Defective Delta P sensor Plugged Delta P ports EGR valve mechanical failure EGR valve leaks VPOD mechanical failure Exhaust leaking at the S pipe Leaking air lines from the VPOD to the actuators (insufficient air supply) Leaking or low vehicle air supply to the VPODs All information subject to change without notice. (Rev. April 2004) 4-9 7SE60 0404 Copyright © 2004 DETROIT DIESEL CORPORATION