SERIES 60 EGR TECHNICIAN'S GUIDE Power Loss Under Heavy Pull In extreme cold ambient conditions, the engine will operate in Condensation Protection . During this mode of operation, the engine boost will be reduced and there is no reduction of power. Operating in this mode is a normal operating condition and will not affect engine life or performance. Note: Trucks operating with winter fronts will experience this condition less often. DDC’s recommendations have not changed regarding winterfront usage. A service bulletin issued years ago will be re issued to restate DDC’s position. Perform the following steps for Power Loss Under Heavy Pull . 1. Check for diagnostic trouble codes.
[a] If Fault Codes are logged, diagnose the logged codes first. 2. Visually inspect the air filter restrictions. [a] If the air filter is clogged or dirty, replace the air filter. 3. Visually inspect the air inlet hoses for soft or collapsed areas. [a] If the air inlet hoses are damaged, replace as necessary. 4. Visually inspect the air inlet for restrictions. [a] If the air inlet has restrictions, clean as necessary. 5. Visually inspect the entire length of the breather tube for kinks. [a] If the breather tube has kinks, repair as necessary. 6. Measure the fuel pressure under heavy loads. [a] If the fuel pressure was spiking or decreasing, perform step 7.
[b] If the fuel pressure was not spiking or decreasing, testing is complete. 7. Remove the fuel pump. [a] If the fuel pump is damaged, replace the fuel pump. [b] If the fuel pump is not damaged, perform step 8. 8. Remove the fuel injectors and inspect for combustion passing the seat. [a] If seats are damaged, replace as necessary. NOTE: The injector may need to be replaced also. [b] If the seats are not damaged, testing is complete. All information subject to change without notice. (Rev. April 2004) 5-3 7SE60 0404 Copyright © 2004 DETROIT DIESEL CORPORATION