SERIES 60 EGR TECHNICIAN'S GUIDE Exhaust Gas Recirculation System Basic Checks Perform the following basic steps to check the exhaust gas recirculating system. For all EGR related concerns (may include exhaust smoke complaints), perform the following steps. If any corrections are made as a result of these checks, test the unit again before proceeding further: Basic checks for all Series 60 EGR engines require the following tools: 1,000 Ohm resistor (low watt) DDR suite 8 or DDDL version 4.2 or higher Volt Ohm Meter Pressure gage 0–200 psi Pressure gage 0–100 psi Check Delta P Sensor Follow these steps to check the Delta-P sensor: 1. Turn ignition ON. 2. Plug in DDR/DDDL. 3.
Read Delta-P counts (EGR DPS) [a] If Delta-P counts read 86–135, verify that the EGR pipes and hoses are correctly assembled from the EGR tube to the Delta-P sensor. Reversed hoses or pipes will create black smoke and surging. Go to step 3[b]. [b] Also inspect carefully for split or leaking pipes or hoses in the EGR mixer tube from the EGR cooler to the intake manifold. If hoses/pipes are correct, Check VPOD Output Pressure . [c] If counts do not fall within the 86–135 range, replace Delta-P sensor; then go to Test. All information subject to change without notice. (Rev. April 2004) 5-9 7SE60 0404 Copyright © 2004 DETROIT DIESEL CORPORATION