Detroit Diesel — Detroit Diesel Series 60 EGR Technician's Guide

DDEC IV TESTING Check VPOD Output Pressure Follow these steps to check both VPOD (EGR valve and VNT) output pressure: NOTE: Listen for air leaks at the VPOD during the test. PERSONAL INJURY To avoid injury from the sudden release of a high-pressure hose connection, wear a face shield or goggles. 1. Disconnect the air hoses from the EGR and VNT (Variable Nozzle Turbine) actuators. 2. Install pressure gauges (accurate to within 1.4 kPa [0.2 psi]) at the outlet of the EGR and VNT hoses. (Use two gauges, or test separately.) 3. Using the DDR/DDDL, activate PWM #2 (EGR) and PWM #4 (VNT) duty cycles and monitor the output pressure from the VPOD. 4. Test: activating 11 % duty cycle:

Pressure = 106 – 134 kPa (15.4 – 19.4 psi). Go to steps 5[a] and 5[b]. 5. Test: activating 90 % duty cycle: Pressure = 485 — 515 kPa (70 – 75 psi). [a] If the VPOD readings are as listed, Check for Active Codes . 5-10 All information subject to change without notice. (Rev. April 2004) 7SE60 0404 Copyright © 2004 DETROIT DIESEL CORPORATION