Detroit Diesel — Detroit Diesel Series 60 EGR Technician's Guide

SERIES 60 EGR TECHNICIAN'S GUIDE [b] If the results in this step cannot be attained, Check VPOD Input Pressure . NOTE: Both activations must operate their component with full travel of the linkage to hit the stops. Check VPOD Input Pressure Follow these steps to check VPOD input pressure: 1. Measure VPOD input pressure to port 1; ensure it is between 703 – 1296 kPa (90 – 120 psi). [a] If the supply pressure is not between 703 – 1296 kPa (90 – 120 psi), troubleshoot the vehicle air system until that result is obtained. [b] If the supply pressure is between 703 – 1296 kPa (90 — 120 psi), Check Variable Output Pressure Device (VPOD) P/N and Supply Voltage .

Check Variable Output Pressure Device (VPOD) P/N and Supply Voltage The following checks should be performed for the VPOD P/N and supply voltage: 1. Check VPOD label to determine if it is + 12V or + 24V compatible. 2. Unplug VPODs mating connector. A 1,000 Ohm resistor is needed for the next step. Insert the resistor between cavity 1 and 3 for ease of checking with the VOM. [a] Turn ignition switch ON. [b] Measure voltage from pin 3 to pin 1. [c] Plug in DDR and check ECM voltage. 3. Is the VPOD P/N and voltage, and ECM voltage correct? [a] If the VPOD P/N and voltage are correct, Check VPOD Wiring .. All information subject to change without notice. (Rev.

April 2004) 5-11 7SE60 0404 Copyright © 2004 DETROIT DIESEL CORPORATION