Illustration 5.2.2 Diesel engine Illustration Maintenance work: Fuel system 50 operating hours after t he initial operation and subsequently, at intervals of 500 operating hours Replace the preliminary fuel fi lter (1): • Use a tensioning belt to open the fi lter cartridge. • Immediately remove any leaking fuel. • EU waste disposal key for the fi lter cartridge: 150299 (EU). • Attach the new fi lter cartridge (1) to the fi lter console by manually screwing it on. • Start the Diesel engine. • Ventilate the fuel system, if required, see Deutz Diesel engine operating manual. Maintenance work:
Cooling system 50 operating hours after t he initial operation and subsequently, at intervals of 500 operating hours Diesel engine cooler: • For instructions related to cleaning the cooling system of the Diesel engine, see Deutz operating manual. • Make sure that the grill for the cooling air intake is not dirty. Clean it, if necessary. Hydraulic oil cooler: • Disassemble the electric fan and protect it against moisture. • Use a high-pressure washer to clean the hydraulic oil cooler from the interior to the exterior.