Kaiyi HR25/30T-9 — 제목없음

Illustration Illustration Maintenance work: Checking the V-belt 50 operating hours after t he initial operation and subsequently, at intervals of 500 operating hours Check the V-belt tension and watch out for damage. WARNING! Never check the V-belt tension with the Diesel engine running! Turn off the Diesel engine and pull out the ignition key. i NOTE! Refer to the Deutz operating and maintenance manual for instructions related to tensioning and replacing the V-belt. Maintenance work: Replacing the combustion air fi lter 50 operating hours after t he initial operation and subsequently, at intervals of 500 operating hours i NOTE!

• If the respective lamp on the dashboard indicates an accumulation of dirt at the air fi lter for the combustion air of the Diesel engine, clean or replace the air fi lter. • After a maximum of fi ve cleanings, by means of compressed air, replace the fi lter cartridge. • Wash and dry the interior of the air fi lter housing and clean it; if necessary, vacuum it. WARNING! Damage to the Diesel engine! Never attempt to clean the air fi lter by blowing air into it!