SEBU7901-01 49 Maintenance Section Refill Capacities Table 8 Table 9 (1) Protection from boiling is increased with the use of a pressurized radiator. NOTICE Do not use propylene glycol in concentrations that ex- ceed 50 percent glycol because of propylene glycol’s reduced heat transfer capability. Use ethylene glycol in conditions that require additional protection against boiling or freezing. (1) Total dissolved solids dried at 103 - 105єC, “Standard Method for the Examination of Water and Wastewater”, American Public Health Association, et al, 1015 15th Street, N.W. Washington, DC 20005 Table 10 DO NOT use the following types of water in cooling systems:
hard water, softened water that has been conditioned with salt, and sea water. Glycol To check the concentration of glycol, use 245-5829 Coolant Test Kit . The testers give readings that are immediate and accurate. The testers can be used with ethylene or propylene glycol. Glycol in the coolant helps to provide protection against the following conditions: Boiling Note: Propylene glycol coolant that is used in Caterpillar diesel engine cooling systems must meet ASTM D6210-04, “Fully-Formulated Propylene Glycol-Based Engine Coolant for Heavy-Duty Engines” standards.
When Propylene glycol is used in heavy-duty diesel engines, Supplemental Coolant Additive (SCA) must be added regularly for protection for the liner cavitation. Consult your Caterpillar dealer for more information. Freezing Cavitation of the water pump and cylinder liners For optimum performance, Caterpillar recommends a 1:1 mixture of a water/glycol solution. Note: Use a mixture that will provide protection against the lowest ambient temperature. Note: 100 percent pure glycol will freeze at a temperature of н 23 °C ( н 9 °F). S·O·S Services Coolant Analysis Testing the engine coolant is important to ensure that the engine is protected from internal cavitation and from corrosion.
The analysis also tests the ability of the coolant to protect the engine from boiling and from freezing. The S·O·S coolant analysis can be done at your Caterpillar dealer. Caterpillar S·O·S coolant analysis is the best way to monitor the condition of your coolant and your cooling system. S·O·S coolant analysis is a program that is based on periodic samples. Most conventional heavy-duty coolants use ethylene glycol. Propylene glycol may also be used. In a 1:1 mixture with water, ethylene and propylene glycol provide similar protection against freezing and boiling. Refer to Tables 9 and 10 for additional information.
Caterpillar Minimum Acceptable Water Requirements Property Maximum Limit ASTM Test Chloride (Cl) 40 mg/L (2.4 grains/US gal) “D512”, “D4327” Sulfate (SO) 4 100 mg/L (5.9 grains/US gal) “D516” Total Hardness 170 mg/L (10 grains/US gal) “D1126” Total Solids 340 mg/L (20 grain/US gal) “Federal Method 2540B”(1) Acidity pH of 5.5 to 9.0 “D1293” Ethylene Glycol Concentration Freeze Protection Boil Protection(1) 50 Percent í37 °C (í34 °F) 106 °C (223 °F) 60 Percent í52 °C (í62 °F) 111 °C (232 °F) Propylene Glycol Concentration Freeze Protection Boil Protection 50 Percent í32 °C (í26 °F) 106 °C (223 °F)