Caterpillar — Caterpillar C11 and C13 Industrial Engines Operation and Maintenance Manual

48 SEBU7901-01 Maintenance Section Refill Capacities Note: Refer to Special Publication, SEBU6251, “Caterpillar Commercial Diesel Engine Fluids Recommendations” for the Caterpillar Specification for distillate fuel and for additional information that relates to fuel for your engine. Table 7 Refill Capacities (Fuel System) Refer to the “Operation and Maintenance Manual” that is provided by the OEM for capacities of the fuel system. Cooling System The following types of coolants may be used in Caterpillar diesel engines: Preferred Cat ELC (Extended Life Coolant) or a commercial extended life coolant that meets the Caterpillar EC-1 specification (1) Use the interval that occurs first.

(2) Refer to this Operation and Maintenance Manual, “Maintenance Interval Schedule” in order to find the correct interval for replacing the water temperature regulator. (3) Cat ELC Extender must be added at 6000 service hours or one half of the service life of the ELC. (4) An extender must be added at 3000 service hours or one half of the service life of the coolant. Acceptable Cat DEAC (Diesel Engine Antifreeze/Coolant) or a commercial heavy-duty coolant that meets “ASTM D4985”, or “ASTM D6210” specifications Note: Cat DEAC does not require a treatment with an SCA (Supplemental Coolant Additive) at the initial fill.

However, a commercial heavy-duty coolant that only meets the “ASTM D4985” specification WILL require a treatment with an SCA at the initial fill. A commercial heavy-duty coolant that meets the “ASTM D6210” specification will NOT require a treatment with an SCA at the initial fill. Read the label or the instructions that are provided by the manufacturer of the commercial heavy-duty coolant. Note: These coolant change intervals are only achievable with annual S·O·S Services Level 2 coolant sampling and analysis. Distilled water or deionized water is recommended for use in engine cooling systems.

If distilled water or deionized water is not available, use water that meets or exceeds the properties that are listed in 8. Note: These coolants WILL require a treatment with a supplemental coolant additive on a maintenance basis. NOTICE Do not use a commercial coolant/antifreeze that on- ly meets the ASTM D3306 specification. This type of coolant/antifreeze is made for light duty automotive applications. Caterpillar recommends a 1:1 mixture of water and glycol. This mixture of water and glycol will provide optimum heavy-duty performance as a coolant.

NOTICE All Caterpillar diesel engines equipped with air-to-air aftercooling (ATAAC) require a minimum of 30 percent glycol to prevent water pump cavitation. Coolant Service Life Coolant Service Life(1)(2) Cat® ELC 965,606 kilometers (600,000 miles), 12000 hours, or 6 years(3) Commercial coolant that meets the Caterpillar EC-1 specification 482,803 kilometers (300,000 miles), 6000 hours, or 6 years(4) CAT® DEAC 321,869 kilometers (200,000 miles), 3000 hours, or 3 years Commercial Heavy-Duty coolant that meets “ASTM D6210” 241,402 kilometers (150,000 miles), 3000 hours, or 2 years Commercial Heavy-Duty coolant that meets “ASTM D4985” 241,402 kilometers (150,000 miles), 3000 hours, or 1 year