74 SEBU7901-01 Maintenance Section Engine Protective Devices - Check 3. Stop the engine and allow the oil to drain back to the sump for a minimum of ten minutes. i01464654 Engine Speed/Timing Sensors - Check/Clean/Calibrate 4. Remove the oil level gauge in order to check the oil level. Maintain the oil level between the “ADD” and “FULL” marks on the oil level gauge. SMCS Code: 1912-040; 1912-070; 1912-524 i00626013 Engine Protective Devices - Check SMCS Code: 7400-535 Alarms and shutoffs must function properly. Alarms provide timely warning to the operator. Shutoffs help to prevent damage to the engine.
It is impossible to determine if the engine protective devices are in good working order during normal operation. Malfunctions must be simulated in order to test the engine protective devices. A calibration check of the engine protective devices will ensure that the alarms and shutoffs activate at the setpoints. Ensure that the engine protective devices are functioning properly. NOTICE During testing, abnormal operating conditions must be simulated. g00765246 Illustration 38 Left side view (1) Secondary speed/timing sensor (2) Primary speed/timing sensor The tests must be performed correctly in order to pre- vent possible damage to the engine. 1.
Remove the speed/timing sensors from the front housing. Check the condition of the plastic end of the speed/timing sensors for wear and/or contaminants. To prevent damage to the engine, only authorized service personnel or your Caterpillar dealer should perform the tests. 2. Clean the metal shavings and other debris from the face of the speed/timing sensors. Use the procedure in the Service Manual in order to calibrate the speed/timing sensors. Visual Inspection Visually check the condition of all gauges, sensors and wiring. Look for wiring and components that are loose, broken, or damaged. Damaged wiring or components should be repaired or replaced immediately.
Refer to the Service Manual for more information on the speed/timing sensors.