daewoo — Daewoo D1146 D1146TI DE08TIS Diesel Engine Maintenance Manual

D1146/D1146TI/DE08TIS MAINTENANCE MANUAL 4. Maintenance of Major Components 4.1. Cooling System 4.1.1. General information This engine is water-cooling type. Heat from the combustion chamber and engine oil heat are cooled down by coolant and radiated to the outside, resulting in the normal operation of the engine. Looking into the cooling system, the water pumped up by the water pump circulates around the oil cooler through the water pipe to absorb the oil heat, and then flows through the water jacket of the cylinder block and water passage of the cylinder head to absorb the heat of the combustion chamber.

The water absorbing the oil heat and combustion chamber heat goes on to the thermostat through the water pipe, and circulates to the water pump if water temperature is lower than the valve opening temperature on the thermostat, while circulating to the radiator at water temperature higher than the valve opening temperature. At the radiator, the heat absorbed in the coolant is radiated to cool down and the coolant recirculates to the water pump. 4.1.2. Specification 98 Printed in Jan. 2001 PS-MMA0415-E1A Item Specification Type Pump speed 1. Water pump Delivery capacity Operation pressure Allowable back pressure Operating temperature 2. Thermostat Valve lift Operating temperature 3.

Cooling fan and belt Fan diameter – Number of blades Fan belt tension Centrifugal type 2,000 rpm 2,700 rpm about 190 liter/min about 280 liter/min 0.5 bar 0.8 bar bellow 0.5 bar 79°C 83°C 8 mm or more 8 mm or more (at 94°C) (at 94°C) 79 ∼ 94°C 83 ∼ 95°C Truck : φ700mm – 8 15mm deflection by thumb