EXCAVATOR OPERATION 40 C One way hold [AUX 1 and 2 modes] Press the one way hold switch of the right attachment control lever, and the oil continues to flow through the AUX port 4. Press this switch again or move the AUX port knob, and the oil flow is interrupted. B Setting the Maximum Flow Volume The AUX port has been factory-set to three action modes 1, 2 and 3. The action modes 4 and 5 can also be preset. C How to make the settings 1. With the starter key at the "RUN" position, press the user setting switch (switch 1), and the following display appears onscreen.
(1) User setting switch (switch 1) (1) Attachment control lever (right) (2) Attachment control lever (left) (3) One way hold switch (right) (B) "AUX port 2" 2. Press the switch 2 or 3 to select "AUX Flow Ctrl Set", and then press the switch 5. A Even if the one way hold switch of the left attachment control lever is pressed, no function is assigned. In this case, the following message appears onscreen. (1) Switch 2 and 3 (2) Switch 5