Mitsubishi Heavy Industries — INSPECTION AND REPAIR

(l) Crankpins (a) Inspect each crankpin for surface flaws such as roughing, scratches, pitting and bums, and, as necessary, repair the crankpins by grinding to the next undersize or replace the crankshaft. (b) Mike each crankpin to take a total of four readings to determine the wear, out-of·round and taper. If any of the limits is exceeded, repair by grinding to the next undersize or replace the crankshaft. Miking crankshaft crankpins Specifications Unit: mm (in.) -29- Item Standard Repair limit Service limit Diameter of journals 65-0.015 -O.oJ5 (2 559-0.00059 .

.-0.00138 -0.15 (-0.0059) -0.9 (-0.035) Out of round· ness of crank· pins and journals om (0.0004), max 0.03 (0.0012) • Taper of crank· pins and journals Diameter of crankpins 58-0.oJ5 -0.055 (228rO.00138) . -0.00217 -0.20 (-0.008) Fit of journals in main bearings 0.03 -0.089 (0.0012 - 0.00350) 0.2 (0.0079) Uneven wear: 0.03 (0.0012)