Mitsubishi Heavy Industries — FUEL SYSTEM

5-4 Testing and adjustment (1) Injection pressure The pressure at which the needle valve unseats itself against the force of the pressure spring is referred to as "valve opening pressure" or "begin- ning-of-injection pressure," but will be called here "injection pressure' for short. The value 01 this pressure is specified; it is checked and adjusted as follows: (a) Install the injection nozzle in the nozzle tester, and operate the manual pumping handle of the tester several strokes to prime the nozzle. (b) Move the lever up and down slowly, completing each up.and-down cycle in about a second, to pressurize the injection nozzle, while observing the indication of the test pressure gauge.

As the nozzle begins to spray, the indicating pointer of the gauge being deflected will start perceptively oscillating: read the pressure right then as the injection pressure. Specifications Unit: kg/cm 2 (psi) (c) If the reading taken is below the limit, increase the thickness of the shim used on the pressure spring. Increasing the shim thickness by 1 mm (0.04 in.) raises the injection pressure by about 10 kg/cm 2 (142 psi). Adjusting shim stock for this purpose is available in 20 sizes, from 1.0 mm (0.0394 in.) up to 1.95 mm (0.0768 in.) in increments of 0.05 mm (0.0020 in.) each. (2) Spray pattern 1 2 3 lllJ lUI II!lI The injection nozzles used in the present engine are of throttle type.

Some throttling action takes place when the needle valve begins to unseat, thereby limiting the amount of fuel being sprayed out during the initial stage of each fuel injection. Thus, each slug of fuel sprayed out may be regarded as consisting of two parts: initial throttled spray and tenninating main spray. 1\ When tested on the nozzle tester, the injection nozzle can be made to produce these two kinds of spray for visual inspection. Initial throttled spray comes about when the tester lever is operated at a rate of 60 cycles per minute (up and down 'in one second); terminating main spray occurs when the lever is operated rapidly at a rate of, say, 4 to 6 cycles per second.

1-Good 4·After-dribble 2-5pray cone too large 5·Fissured spray 3-Off-i:enter spray 6-Whirling spray Possible patterns of spray -62- Item Standard Repair limit Injection pressure 120+1g 1706.4+145.2 ( ) 110(1564.2) minimum