Do not jump into a conclusion that th.e starter is in trouble when the engine refuses to fire up upon cranking: the engine could be in trouble. 6. Preheating system Removal and installation of glow plugs (1) Before removing glow plugs from the engine, be sure to disconnect battery terminals. (b) No-load test If the starter is suspected of trouble, take it down from the engine and run a no-load test on it to find out if it is really in trouble. (2) Disconnect cable (1) from No.4 cylinder glow plug. Loosen glow plug connection plate attaching nut (2) and remove connection plate (3). When removing the starter, be sure to have the battery switch turned off.
Switch I I -9 -EB J8843 No·load test circuit 402591 '·Cable 2·Nut 3-Connection plate Here's how to carry out the no-load test: Form a test circuit with a voltmeter and an ammeter, as shown, using a fully charged 24-volt battery; close the switch to run the starter until its speed rises to and above 4000 rpm; and then read the voltmeter and ammeter when the starter is spin- ning. The ammeter should show that the starter is drawing not more than 130 amperes, with the voltmeter indicating at least 11 volts (at the speed of at least 4000 rpm); if not, estimate the cause of the trouble by consulting the troubleshooting guide, which follows: (3) Remove all glow plugs from the cylinder head.
Take out packings from glow plug installation holes. (4) To install, follow the reverse of removal procedure. 7. Inspection and adjustment 7 -1 ·Starter (1) Inspection before disassembly (a) Checking the starting circuit for operation With the starter in place, check to be sure that - 1) The battery is in good condition, with its cell plates showing no evidence of "sulfation" or any other faulty condition, and is in fully charged state. 2) The battery terminal connections are clean and tight. 3) The starter terminal connections are tight. 4) The wires are securely connected to terminals, and are free of any insulation stripping due to fraying, there being no signs of grounding or breaking.
5) The starter switch closes and opens the circuit positively at each position. - 81-