Starter troubleshooting guide 670202 (b) A growler is generally used to test armature for short circuit in its Winding. Place armature on a growler, and rotate it slowly while holding a steel strip over armature. If there is any short circuit between cores, the strip will vibrate and be at- tracted to armature. If so, replace armature. (c) Measure commutator runout with a dial gauge. Repair commutator if the runout exceeds the limit. The best way of testing the starter is to run it under loaded condition, but that requires special testing equipment. For ordinary servicing pur- poses, the no-load test and troubleshooting guide will do.
(2) Inspection after disassembly (a) Using a ground tester or megger, check armature coil and commutator for short circuit. If there is any continuity between commutator and ar- mature shaft, armature coil and commutator are short circuited. Specifications Unit: mm (in.) -82- Symptom Possible cause Large current and low speed 1) Bearings are dirty, or need lubrication. 2) Rotor (armature core) is rubbing the pole pieces. 3) Grounded coil in the armature or in the field. 4) Short-circuit in the armature coils. Large current but no speed 1) Magnetic switch is grounded and is not working. 2) Grounded coil in the armature or in the field. 3) Seized bearing.
No current and no speed 1) Open-circuited coil in the armature or in the field. 2) Broken brush pigtail. 3) No conduction between brushes and commutator because of "high mica" con- dition or dirty commutator surface. Small current and low speed and torque Loose coil connection in the field. Very large current, very high speed and low torque Short-circuited field coil. Item Assembly standard Repair limit Grinding limit Commutator runout 0.05 (0.0020) 0.3 (0.012) 31 (1.22)