Komatsu — WHEN REQUIRED

. MAINTENANCE SERVICE PROCEDURE PROCEDURE FOR RELEASING INTERNAL PRESSURE OF HYDRAULIC SYSTEM WARNING 4 - 46 The hydraulic s ternal pressure, so when inspecting or replac ing the piping or hose s, releas e the internal pressu re in the circuit. If the pre ssure is not release d, high-pressure oil will s purt out and ca use serious personal injury. Immediately aft er the engine is stopped, the parts and the oi l are at a high temperatur e, and will caus e burns . Wait fo r the temperature to go down before starting t When the cap o f the oil filler port is remo ved, oil may spurt o ut, so turn the cap slowly t o release the in ternal p ressure, then remove it caref 1.

Stop the ma chine on firm level gro 2. Lower the bl ade completely to the g round and stop the engine. 3. After stoppin g the engine, turn the starting switch to the ON equipment lock lever to the FREE position. ON position. 4. Set the work equipment lock lever to the FREE positi To release lever in each the internal pressure, direction to the end of i operate the blade ts stroke within 15 s control econds after stoppin g the engine. 6. Loosen oil fil ler cap (F) at the top of the hydraulic tank s lowly to release the i