Komatsu — CHECK AFTER SHUT OFF ENGINE

MACHINE OPERATIONS AND CONTROLS OPERATION STOPPING THE ENGINE NOTICE If the engine is abruptly stopped before it has cooled down, engine life may be greatly shortened. Conse- quently, do not abruptly stop the engine apart from an emergency. In particular, if the engine has overheated, do not abruptly stop it but run it at mediumspeed to allow it to cool gradually, then stop it. 1. Run the engine at low idling speed for about 5 minutes to allow it to gradually cool down.

When carrying out inspection or maintenance of the machine after the engine has been stopped, see "METHOD OF RELEASING PRESSURE IN HYDRAULIC CIRCUIT (PAGE 4-64)", and release the hydraulic pressure remaining inside the work equipment piping. CHECK AFTER SHUT OFF ENGINE 1. Walk around the machine and check the work equipment, machine exterior, and undercarriage, and check also for leakage of oil or water. If any abnormalities are found, repair them. 2. Fill the fuel tank. 3. Check the engine compartment for paper and debris. Clean out any paper and debris to avoid a fire hazard. 4. Remove any mud affixed to the undercarriage. 3-64 2.

Turn the key in starting switch (1) to the OFF position and stop the engine. 3. Remove the key from starting switch (1). REMARK